Error Code: E23 Difficulty: Hard
Problem: The frequency of the capacitive level sensor is outside the acceptable range.
How to Fix E23 Error (Step-by-Step)
- Ensure the dryer is completely disconnected from power and confirm the error stays cleared during a full test cycle.
- Locate the capacitive level sensor (Part 5304521373), which is part of the main control board assembly in many models.
- Access the main control board, typically behind the top or front control panel.
- Carefully disconnect the wiring harnesses connected to the board and confirm the error stays cleared during a full test cycle.
- Unmount and remove the entire control board assembly and confirm the error stays cleared during a full test cycle.
- Replace it with the new control board/sensor assembly and confirm the error stays cleared during a full test cycle.
- Securely reconnect all wiring and reassemble the dryer panels before restoring power.
- Turn the appliance off, wait about 2 minutes, then turn it back on.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Electrolux error codes: Electrolux Error Codes