Problem: Water supply error – low flow rate or pressure switch fault
How to Fix 4E Error
- Clean inlet valve screens as per nF procedure.
- Verify water pressure minimum 20 PSI at source with gauge.
- Inspect pressure hose connection at tub top air dome – ensure not cracked or disconnected.
- Blow through pressure tube to clear moisture blockage (tube must be completely dry).
- Test pressure switch operation: disconnect tube, apply gentle suction while monitoring multimeter on switch terminals (should toggle at ~
- 5 PSI).
- Replace water level sensor DC96-01703C if switch fails continuity test or frequency output unstable.
- Check for air leaks in pressure system – submerge tube ends in water while running diagnostic fill cycle to spot bubbles indicating leaks.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Samsung error codes: Samsung Error Codes