  • How to Fix GE Dryer Error 001

    How to Fix GE Dryer Error 001

    Problem: Inlet thermistor failure – temperature sensor reading out of range

    How to Fix 001 Error

    1. UNPLUG THE DRYER. This code indicates the inlet thermistor has failed (open circuit or out of range).
    2. The inlet thermistor is located on the blower housing or heater assembly. Remove the front or rear panel to access it.
    3. Disconnect the wire harness from the thermistor. Use a multimeter set to Ohms (Ω) to test its resistance.
    4. At room temperature (~77°F/25°C), it should read approximately 10,000 ohms (10kΩ). An ‘open’ or infinite reading (often displayed as ‘OL’) confirms it’s bad.
    5. Unscrew the old thermistor, install the new one, reconnect the wiring, and reassemble the dryer.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 002

    How to Fix GE Dryer Error 002

    Problem: Outlet thermistor failure – temperature sensor open or reading out of range

    How to Fix 002 Error

    1. UNPLUG THE DRYER. This code indicates the outlet thermistor has failed (open circuit or out of range).
    2. The outlet thermistor is located on the heater duct assembly, accessible by removing the dryer’s rear panel.
    3. Disconnect the wire harness and test the thermistor’s resistance with a multimeter.
    4. A functional thermistor should read around 10,000 ohms (10kΩ) at room temperature. If you get an infinite reading (OL), it has failed.
    5. Replace the faulty thermistor, reconnect the wiring, and reinstall the rear panel.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 003

    How to Fix GE Dryer Error 003

    Problem: Inlet thermistor issue – variant code for inlet temperature sensor

    How to Fix 003 Error

    1. UNPLUG THE DRYER from the wall outlet to ensure safety.
    2. The inlet thermistor is usually located on the blower housing or the heater assembly. You will need to remove the dryer’s front or rear panel to access it.
    3. Disconnect the wire harness from the thermistor. Use a multimeter set to Ohms (Ω) to test the resistance across the two terminals.
    4. At room temperature (~77°F/25°C), it should read approximately 10,000 ohms (10kΩ). If the reading is infinite (open circuit) or near zero (shorted), the thermistor has failed.
    5. Remove the screw holding the old thermistor, install the new one, and reconnect the wire harness. Reassemble the dryer panel.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 004

    How to Fix GE Dryer Error 004

    Problem: Outlet thermistor shorted – temperature sensor circuit shorted

    How to Fix 004 Error

    1. Disconnect the dryer from its power source completely.
    2. The outlet thermistor is typically located on the heater duct assembly. Accessing it usually requires removing the rear panel of the dryer.
    3. Unplug the electrical connector from the thermistor. Set your multimeter to the Ohms setting.
    4. A ‘shorted’ reading means the resistance is at or near zero ohms. A functional thermistor should read around 10,000 ohms at room temperature.
    5. If the thermistor is confirmed shorted, unscrew it from the duct, replace it with the new part, and securely reconnect the wiring. Reassemble the dryer.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 005

    How to Fix GE Dryer Error 005

    Problem: Main control board defective – control board failure

    How to Fix 005 Error

    1. UNPLUG THE DRYER. This is a critical error indicating the main control board is defective.
    2. Perform a hard reset by leaving the dryer unplugged for 10 minutes. If the code returns, the board must be replaced.
    3. Follow the procedure for code F01: Locate the main board, take a photo of the wiring, label and disconnect all harnesses, swap the board, and carefully reconnect everything.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 006

    How to Fix GE Dryer Error 006

    Problem: Stuck button on control panel – a button is continuously pressed

    How to Fix 006 Error

    1. UNPLUG THE DRYER. This error means a button on the user interface (UI) is stuck.
    2. First, try gently pressing and wiggling each button on the control panel to see if you can free the stuck one. Sometimes wiping the panel with a damp cloth can help.
    3. If that doesn’t work, the UI board needs to be replaced. Access the board by removing the top control console panel.
    4. Disconnect the ribbon cable(s) and any other wire harnesses from the old UI board. Remove its mounting screws.
    5. Install the new UI board, reconnect all wiring, and reassemble the console.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 007

    How to Fix GE Dryer Error 007

    Problem: Power supply mis-wired – Line 2 (L2) and Neutral (N) are reversed

    How to Fix 007 Error

    1. UNPLUG THE DRYER IMMEDIATELY. This is a dangerous wiring condition that poses a shock hazard.
    2. This error means the 240V power outlet or the dryer’s power cord is wired incorrectly. The dryer is detecting that the Line 2 (hot) and Neutral wires are swapped.
    3. DO NOT use the dryer. You must contact a qualified electrician to inspect and correct the wiring of the wall outlet and the dryer’s terminal block.
    4. This is not a fault with the dryer’s components, but with its electrical installation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 008

    How to Fix GE Dryer Error 008

    Problem: Door latch stuck / door switch not opening after five cycles

    How to Fix 008 Error

    1. UNPLUG THE DRYER. This error indicates the door switch is not registering as open, or the latch is physically stuck.
    2. First, check the physical latch and strike for anything causing it to bind. Clean the area.
    3. If it’s not a physical jam, the door switch has failed. Access the switch by removing the dryer’s top or front panel.
    4. Use a multimeter to test the switch. It should show an open circuit when the plunger is not pressed. If it shows continuity at all times, it’s stuck closed and must be replaced.
    5. Swap the faulty switch with the new part, reconnect the wiring, and reassemble.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 009

    How to Fix GE Dryer Error 009

    Problem: Dry load detection trip – dryer failing to detect heat

    How to Fix 009 Error

    1. This code indicates the dryer ran but did not detect a temperature change, often because the load was already dry or too small.
    2. Open the door and check the clothes. If they are dry, this code is informational and can be cleared.
    3. If the clothes are still wet, it means the dryer is not heating, which is a separate issue to investigate (see codes HE, E
    4. .
    5. For very small loads, add a few larger items (like towels) to ensure the load tumbles properly and makes contact with the moisture sensors.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes

  • How to Fix GE Dryer Error 00d

    How to Fix GE Dryer Error 00d

    Problem: Door switch not opening – alias of 008

    How to Fix 00d Error

    1. UNPLUG THE DRYER. This is an alias of code 008, indicating a faulty door switch.
    2. Open the dryer door and locate the screws holding the front panel or top panel in place. Remove the panel to gain access to the door switch assembly, located where the door frame meets the cabinet.
    3. Disconnect the wire harness from the switch. Use a multimeter to test for continuity.
    4. The switch should show continuity only when its plunger is pressed in, and no continuity (open) when released. If it shows continuity in both states or never shows continuity, it’s defective.
    5. Remove the old switch (it usually snaps or screws into place), install the new one, and reconnect the wiring. Reassemble and test.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Ge error codes: Ge Error Codes