Author: ApplianceFixGuide Team

  • How to Fix Maytag Dryer Error 6E

    How to Fix Maytag Dryer Error 6E

    Problem: Ambient temperature too low for proper thermistor operation—below 40°F/4°C

    How to Fix Dryer Error

    1. Verify room temperature where dryer is installed—must be above 40°F (4°C) for proper operation.
    2. If installed in unheated space (garage, basement), provide supplemental heating during cold weather or relocate dryer to heated area.
    3. Test inlet thermistor WP35001191 resistance at current ambient temperature—should follow standard thermistor curve (approximately 35k ohms at 40°F, 10k ohms at 70°F).
    4. If thermistor reading doesn’t track ambient temperature correctly, replace WP
    5. Inspect thermistor mounting—must be positioned in airflow path, not touching metal housing which conducts cold.
    6. Check for drafts directly hitting thermistor location—seal gaps in dryer cabinet if needed.
    7. After ambient temperature rises above 40°F, power cycle dryer (unplug 1 minute) to clear 6E code.
    8. Run test cycle to verify proper temperature monitoring and cycle termination.
    9. For permanent cold-location installations, consider installing thermostatically controlled space heater to maintain minimum 45°F ambient temperature.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error 7E

    How to Fix Maytag Dryer Error 7E

    Problem: Temperature control error—overheating detected by multiple sensors

    How to Fix Dryer Error

    1. IMMEDIATE ACTION: Disconnect power—serious overheating condition exists.
    2. Remove rear panel to access heater assembly and thermal protection devices.
    3. Test thermal fuse WP3392519 on blower housing—replace if open (blown).
    4. Test high-limit thermostat WP3392914—replace if open (tripped).
    5. Inspect heating element for grounded windings causing continuous heating—test continuity between element terminals and metal housing (should be open circuit).
    6. Verify blower wheel integrity—cracked or missing fins reduce airflow causing overheating. Replace wheel if damaged.
    7. Inspect entire vent system for severe blockages: remove lint screen and clean thoroughly, disconnect flexible hose and clean with vent brush, verify exterior vent flap opens fully.
    8. Check drum seals for tears allowing air bypass—replace if damaged.
    9. Replace thermal fuse WP3392519 and high-limit thermostat WP3392914 as a set.
    10. After repair, run first test cycle with vent disconnected while monitoring exhaust temperature—should cycle normally without exceeding 180°F. Reconnect vent only after verifying proper operation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Whirlpool Washer Error F20

    How to Fix Whirlpool Washer Error F20

    Problem: No water detected entering washer during fill cycle

    How to Fix Washer Error

    1. Verify both hot and cold water supply valves are fully open.
    2. Disconnect fill hoses from washer inlet valves and place in bucket.
    3. Turn on water supply briefly to verify adequate flow (should fill bucket rapidly).
    4. Clean inlet valve screens by removing hoses and brushing debris from brass fittings.
    5. Check for kinks in fill hoses or excessive length (>6 feet restricts flow).
    6. Access inlet valve assembly behind rear panel – test solenoid coils with multimeter (should read 500-1500 ohms).
    7. If solenoids test open/infinite resistance, replace water inlet valve assembly W
    8. Verify pressure switch hose is connected and not leaking air (causes False ‘full’ detection).
    9. Test operation with both hot and cold cycles to confirm proper fill.
    10. If water flows but error persists, replace pressure switch W

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F14

    How to Fix Whirlpool Washer Error F14

    Problem: Control board watchdog timer failure – processor locked up

    How to Fix Washer Error

    1. Unplug washer for 5 minutes to reset processor.
    2. Inspect main control board for signs of overheating (discolored components near processor).
    3. Check ventilation around control compartment – ensure no lint buildup blocking airflow.
    4. Verify ambient temperature isn’t exceeding 120°F near control board location.
    5. Test all input devices (lid switch, door lock, pressure switch) for intermittent shorts that could crash processor.
    6. If no external causes found and error recurs within 3 cycles, control board processor has failed.
    7. Replace main control board assembly W
    8. During installation, apply thermal compound to processor heat sink if provided with new board.
    9. After replacement, monitor washer through 3 complete cycles to confirm stability.
    10. Document any power interruptions that preceded failure – may indicate need for UPS protection.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F13

    How to Fix Whirlpool Washer Error F13

    Problem: EEPROM checksum error on main control board

    How to Fix Washer Error

    1. Unplug washer for 10 minutes to fully discharge board capacitors.
    2. Remove top panel and locate main control board (CCU).
    3. Inspect board for visible damage: burnt components, bulging capacitors, or moisture corrosion.
    4. Check all wire harness connections for proper seating and corrosion.
    5. Verify 120V AC power supply to board is stable (no voltage sags during operation).
    6. If board appears physically intact but error persists after power cycle, EEPROM corruption has occurred.
    7. Main control board must be replaced – EEPROM cannot be reprogrammed in field.
    8. Install new CCU W10461397 and secure all mounting screws to prevent vibration damage.
    9. After installation, run full diagnostic cycle to verify all functions operate correctly.
    10. Note: Power surges often cause this failure – recommend installing whole-house surge protector.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F11

    How to Fix Whirlpool Washer Error F11

    Problem: Serial communication error between main control board (CCU) and motor control unit (MCU)

    How to Fix Washer Error

    1. Unplug washer for 2 minutes to reset communication bus.
    2. Remove top panel and locate main control board (CCU) in upper right corner.
    3. Disconnect and reconnect all harnesses at CCU, especially the 3-wire serial communication cable (usually white connector with blue wires).
    4. Inspect harness for pinched wires between tub and cabinet.
    5. Remove rear panel to access MCU and verify its communication connector is fully seated.
    6. Check for water damage or corrosion on both boards’ communication ports.
    7. Measure resistance between communication lines (should be 100-120 ohms between data lines).
    8. If harness tests good but error persists, replace MCU W10312695 first (less expensive).
    9. If F11 returns, replace main control board W
    10. After repair, enter diagnostic mode and verify all communication LEDs function properly.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F10

    How to Fix Whirlpool Washer Error F10

    Problem: Motor control unit internal failure or communication timeout

    How to Fix Washer Error

    1. Power cycle washer by unplugging for 5 minutes.
    2. Remove rear access panel to expose motor control unit (MCU).
    3. Inspect all connectors at MCU for corrosion, bent pins, or loose seating – reseat firmly.
    4. Check 3-wire serial communication harness between MCU and main control board (CCU) for damage.
    5. Verify 120V AC power reaches MCU during operation (test at L1/L2 terminals).
    6. Measure DC voltage at MCU output to motor (should be 30-150V DC variable depending on speed).
    7. If power present but no motor operation, replace MCU assembly W
    8. After replacement, run diagnostic mode verifying communication handshake between CCU and MCU.
    9. If F10 returns after MCU replacement, suspect main control board failure requiring CCU replacement.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F09

    How to Fix Whirlpool Washer Error F09

    Problem: Overflow condition detected – pressure switch stuck closed or control board fault

    How to Fix Washer Error

    1. Unplug washer immediately to prevent flooding.
    2. Check base pan for standing water indicating actual overflow.
    3. Remove top panel to access pressure switch mounted on right side wall.
    4. Disconnect pressure hose from switch and blow through it to clear moisture/debris.
    5. With hose disconnected, multimeter should show NO continuity across switch terminals.
    6. Reconnect hose and gently blow into it while monitoring continuity (should close at ~
    7. 5 PSI).
    8. If switch stuck closed (always shows continuity), replace pressure switch W
    9. Inspect pressure hose for cracks, kinks, or water accumulation (replace if damaged).
    10. If switch tests good but error persists, replace main control board W
    11. After repair, run diagnostic cycle monitoring water level detection.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F08

    How to Fix Whirlpool Washer Error F08

    Problem: Heater relay failure or open heater circuit

    How to Fix Washer Error

    1. Unplug washer and turn off water supply.
    2. Remove lower front panel to access heater assembly.
    3. Locate heating element (typically 1800W) mounted on outer tub.
    4. Disconnect wiring harness from heater terminals.
    5. Measure resistance across heater terminals with multimeter (should read 15-25 ohms).
    6. If infinite resistance, replace heating element W
    7. If heater tests good, check continuity of heater relay on main control board (requires board removal).
    8. Inspect wiring harness between control board and heater for damage or rodent chewing.
    9. Verify proper voltage (120V AC) reaches heater terminals during heat cycle using multimeter.
    10. Replace main control board W10461397 if relay is faulty.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes

  • How to Fix Whirlpool Washer Error F07

    How to Fix Whirlpool Washer Error F07

    Problem: Triac short circuit detected in motor control module

    How to Fix Washer Error

    1. Immediately unplug washer – triac failure can cause electrical hazards.
    2. Remove rear panel to access motor control unit (MCU).
    3. Visually inspect MCU board for burnt components, bulging capacitors, or charred areas near triac locations.
    4. Disconnect all harnesses from MCU and check for moisture intrusion or corrosion.
    5. Test continuity between motor terminals and ground (should be infinite resistance; any reading indicates short).
    6. If motor tests good, replace MCU assembly W
    7. Before reinstalling, verify no foreign objects are contacting motor wiring.
    8. After replacement, run diagnostic cycle monitoring motor operation at low/high speeds.
    9. If F07 returns immediately, inspect main control board (CCU) for output stage damage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Whirlpool error codes: Whirlpool Error Codes