  • How to Fix Maytag Dryer Error ERR

    How to Fix Maytag Dryer Error ERR

    Problem: Door not fully closed/latched or door switch not detecting closed position

    How to Fix Dryer Error

    1. Open and firmly reclose dryer door—listen for distinct latch click.
    2. Inspect door gasket for tears, folds, or debris preventing full closure—clean or replace as needed.
    3. Check door strike plate alignment on front panel—should engage latch mechanism fully without binding.
    4. Manually test door switch operation: with door closed, gently press on door near latch area—dryer should start if switch was marginally engaged.
    5. If door appears fully closed but error persists, unplug dryer and remove front lower panel to access door switch WPW
    6. Inspect switch plunger alignment—door strike must fully depress plunger when closed. Adjust strike plate position if misaligned (loosen mounting screws slightly and reposition).
    7. Test door switch continuity with multimeter—replace WPW10441007 if faulty (see F5E1 procedure).
    8. Check door hinge screws for looseness—tighten if door sags preventing proper closure.
    9. After adjustments, close door firmly and press START—error should clear automatically.
    10. If error returns consistently, control board door sense circuit may be faulty—replace WPW10111608 after verifying switch and wiring.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error tS

    How to Fix Maytag Dryer Error tS

    Problem: Thermistor short circuit—Neptune series display code equivalent to F3E3

    How to Fix Dryer Error

    1. Unplug Neptune dryer and remove front lower panel (typically 4 screws at bottom front).
    2. Locate thermistor WP35001191 mounted on blower housing near air inlet.
    3. Disconnect wiring harness from thermistor terminals.
    4. Set multimeter to resistance mode and measure across thermistor leads at room temperature.
    5. Normal reading: 10k-12k ohms at 70°F. tS code indicates short circuit—reading below 500 ohms.
    6. Inspect thermistor body for cracks, moisture damage, or physical deformation causing internal short.
    7. Remove mounting screw securing thermistor to housing.
    8. Extract old thermistor and install new WP35001191, ensuring sensor tip protrudes fully into air stream path.
    9. Reconnect wiring harness with terminals fully seated—verify no exposed wire strands.
    10. To clear tS code: press and hold SENSOR DRY LEVEL and TIME buttons simultaneously for 3 seconds until display resets.
    11. Run test cycle to verify proper temperature monitoring.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error t5

    How to Fix Maytag Dryer Error t5

    Problem: Thermistor short circuit—Neptune series alternate display for tS code

    How to Fix Dryer Error

    1. Unplug Neptune dryer and remove front lower panel to access blower housing.
    2. Locate thermistor WP35001191 mounted on air inlet duct.
    3. Disconnect wiring harness and measure resistance with multimeter—short circuit indicated by reading below 500 ohms (normal: 10k-12k ohms at room temp).
    4. Remove mounting screw and extract faulty thermistor.
    5. Install new thermistor WP35001191 ensuring proper seating in mounting hole with sensor tip facing airflow.
    6. Reconnect wiring harness securely.
    7. To clear t5 code: press and hold SENSOR DRY LEVEL and TIME buttons simultaneously for 3 seconds until display resets to normal.
    8. Power on dryer and select any cycle—error should not return.
    9. Run test cycle monitoring drying performance—cycle should terminate appropriately based on load moisture content.
    10. If t5 returns after replacement, inspect wiring harness for short circuit between thermistor and control board—repair or replace harness as needed.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d1

    How to Fix Maytag Dryer Error d1

    Problem: Diagnostic code: Door sense circuit failure on control board or power line interference

    How to Fix Dryer Error

    1. Enter diagnostic mode per model procedure (typically hold CHIME + TEMPERATURE buttons 3 seconds).
    2. Observe if d1 appears consistently or intermittently—intermittent suggests wiring issue; consistent suggests board failure.
    3. Unplug dryer and remove front lower panel to access door switch WPW10441007 wiring.
    4. Inspect harness for damage near door hinge—repair any broken wires with high-temperature connectors.
    5. Test door switch continuity—replace WPW10441007 if faulty.
    6. Disconnect door switch harness at control board WPW10111608 and inspect pins for corrosion—clean with contact cleaner.
    7. Reseat connector firmly and exit diagnostic mode.
    8. If d1 returns immediately, control board door sense circuit has failed—replace WPW
    9. After replacement, re-enter diagnostic mode and verify d1 code no longer appears in fault history.
    10. Run full diagnostic cycle to confirm all sensors and actuators function correctly.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d4

    How to Fix Maytag Dryer Error d4

    Problem: Diagnostic code: Motor circuit failure—open winding or failed start capacitor

    How to Fix Dryer Error

    1. Enter diagnostic mode and run motor test cycle—note if motor hums but won’t start (capacitor) or remains silent (open winding).
    2. Unplug dryer and remove rear panel to access motor WPW
    3. Disconnect wiring harness from motor terminals.
    4. Set multimeter to resistance mode and test windings: Main winding (typically terminals 1-
    5. should read 2-6 ohms; Start winding (terminals 2-
    6. should read 4-8 ohms. Infinite resistance indicates open winding—replace motor.
    7. Test start capacitor (typically 5-8 MFD) with capacitance meter—reading below 80% of rated value indicates weak capacitor.
    8. If capacitor weak but windings good, replace capacitor WP3392519 ($
    9. .
    10. If windings open or shorted, replace entire motor assembly WPW
    11. During installation, verify blower wheel is securely fastened to motor shaft (setscrew tight).
    12. Reconnect wiring harness ensuring correct terminal assignment per wiring diagram.
    13. Exit diagnostic mode and run test cycle—motor should start immediately and run smoothly without overheating.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d5

    How to Fix Maytag Dryer Error d5

    Problem: Diagnostic code: Coin mechanism circuit error (commercial models) or control board relay failure

    How to Fix Dryer Error

    1. For residential models without coin mechanism, d5 indicates control board relay failure.
    2. Unplug dryer and remove rear panel to access control board WPW
    3. Inspect board for burnt components near relay banks—especially motor and heater relays.
    4. Test relay coils for continuity (80-150 ohms typical)—infinite resistance indicates open coil.
    5. Test relay contacts for proper operation: de-energized = open circuit; energized = continuity.
    6. If any relay fails tests, control board must be replaced—relays are not serviceable individually.
    7. For commercial coin-op models: inspect coin mechanism wiring harness for damage, verify harness fully connected to control board, clean coin acceptor mechanism of debris.
    8. Replace control board WPW10111608 with exact model match.
    9. After installation, enter diagnostic mode and run all actuator tests to verify proper relay operation.
    10. Clear fault history per service manual procedure to prevent d5 from reappearing on display.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d9

    How to Fix Maytag Dryer Error d9

    Problem: Diagnostic code: Low voltage detected at control board power supply

    How to Fix Dryer Error

    1. Disconnect power and remove rear panel to access power cord terminal block.
    2. Restore power and measure voltage at terminal block: L1-Neutral=120V, L2-Neutral=120V, L1-L2=240V. Voltage below 105V on either leg triggers d
    3. If household voltage low, contact utility company—may indicate neighborhood transformer issue.
    4. If voltage correct at terminal block but d9 persists, test voltage at control board power supply input terminals.
    5. Inspect control board WPW10111608 for failed filter capacitors on power supply section—bulging/leaking tops indicate failure.
    6. Test power supply output voltages if schematic available (typically 5VDC and 12VDC rails)—out of spec indicates board failure.
    7. Control board cannot be economically repaired—replace WPW10111608 assembly.
    8. Before replacement, verify no short circuits exist downstream that could damage new board: test heating element for ground faults, motor windings for shorts.
    9. After installation, measure control board supply voltages to confirm proper operation.
    10. Run diagnostic cycle to verify all functions operate correctly at proper voltage levels.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d12

    How to Fix Maytag Dryer Error d12

    Problem: Diagnostic code: Motor sensor circuit failure—failed tachometer or Hall effect sensor

    How to Fix Dryer Error

    1. Enter diagnostic mode and run motor speed test—observe if RPM reading displays correctly or shows error.
    2. Unplug dryer and remove rear panel to access motor WPW
    3. Locate tachometer/Hall sensor mounted on motor end bell (typically 2-3 wire harness).
    4. Disconnect sensor harness and inspect for damage or corrosion.
    5. Test sensor output per manufacturer specifications (typically requires oscilloscope to verify pulse signal while manually rotating motor shaft).
    6. If sensor output absent or erratic, motor assembly must be replaced—sensor is integrated into motor housing and not serviceable separately.
    7. Remove motor mounting bolts and belt tensioner to extract motor assembly.
    8. Transfer blower wheel to new motor WPW10438706 if not included—ensure setscrew tightens securely on shaft flat.
    9. Reinstall motor with proper belt tension (idler pulley should deflect 1/2-3/4 inch when pressed).
    10. Exit diagnostic mode and run test cycle—verify motor reaches proper RPM and maintains speed under load.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d16

    How to Fix Maytag Dryer Error d16

    Problem: Diagnostic code: Moisture sensor circuit failure or communication error

    How to Fix Dryer Error

    1. Enter diagnostic mode and run moisture sensor test—observe resistance reading with dry vs. damp cloth on sensor bars.
    2. Unplug dryer and open door to locate moisture sensor bars inside drum opening.
    3. Clean bars thoroughly with isopropyl alcohol to remove fabric softener residue.
    4. Remove front lower panel to access sensor wiring harness connection at control board.
    5. Disconnect harness and inspect terminals for corrosion—clean with electronic contact cleaner if needed.
    6. Measure resistance across sensor terminals at board—should read 1-2 megohms when dry. Near-zero resistance indicates shorted sensors.
    7. If cleaning and reseating connections doesn’t resolve issue, replace moisture sensor assembly WPW
    8. Route new harness carefully avoiding pinch points near drum rotation path.
    9. Reconnect to control board ensuring secure connection.
    10. Exit diagnostic mode and clear fault history per service manual procedure. Run test load with damp towels to verify sensor extends drying time appropriately.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error d17

    How to Fix Maytag Dryer Error d17

    Problem: Diagnostic code: Door sense error on control board—intermittent door switch signal

    How to Fix Dryer Error

    1. Enter diagnostic mode and observe door status indicator while opening/closing door repeatedly.
    2. Unplug dryer and remove front lower panel to access door switch WPW
    3. Inspect wiring harness near door hinge for damage from repeated flexing—repair any broken wires.
    4. Test door switch continuity while manually operating plunger—should show clean transition between open and closed states without intermittent flickering.
    5. If switch shows intermittent continuity, replace WPW
    6. Check door strike plate alignment—misalignment causes partial switch engagement triggering intermittent signals. Adjust strike plate position if needed.
    7. Inspect door gasket for tears or debris preventing full closure—replace or clean as needed.
    8. Reconnect all wiring and exit diagnostic mode.
    9. Test door operation 10 times consecutively—dryer should start reliably each time with door closed.
    10. Clear fault history per service manual to prevent d17 from reappearing on display.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.



    Browse all Maytag error codes: Maytag Error Codes