Problem: Freezer thermistor out of range – sensor reading implausible temperature (< -25°F or > 80°F) indicating open/short circuit
How to Fix Refrigerator Error
- Unplug refrigerator.
- Locate freezer thermistor: behind rear interior panel near evaporator coils (small white sensor clipped to evaporator tubing).
- Disconnect thermistor harness.
- Measure resistance at room temperature (70°F): should read 8,000-10,000Ω. At 32°F: ~7,964Ω. At 0°F: ~23,345Ω.
- If reading infinite (open) or 0Ω (short), replace thermistor WPW
- If resistance within spec, check wiring harness continuity back to main board J3 connector – look for pinched wires near hinge areas.
- If wiring good but code persists, test defrost thermostat WPW10316428 (clipped to evaporator) – should read closed below 40°F.
- Last resort: main control board W10868991 has failed ADC circuit – replace board and reprogram.
As an Amazon Associate, we earn from qualifying purchases through links on this page.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Maytag error codes: Maytag Error Codes