Problem: Freezer thermistor out of range – sensor reading implausible temperature (< -25°F or > 80°F) indicating open/short circuit
How to Fix Refrigerator Error
- Unplug refrigerator.
- Locate freezer thermistor: behind rear interior panel near evaporator coils (small white sensor clipped to evaporator tubing).
- Disconnect thermistor harness.
- Measure resistance at room temperature (70°F): should read 8,000-10,000Ω. At 32°F: ~7,964Ω. At 0°F: ~23,345Ω.
- If reading infinite (open) or 0Ω (short), replace thermistor WPW
- If resistance within spec, check wiring harness continuity back to main board J3 connector – look for pinched wires near hinge areas.
- If wiring good but code persists, test defrost thermostat WPW10316428 (clipped to evaporator) – should read closed below 40°F.
- Last resort: main control board W10868991 has failed ADC circuit – replace board and reprogram.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Maytag error codes: Maytag Error Codes