Problem: User interface display failure
How to Fix Dryer Error
- Disconnect power at circuit breaker.
- Remove control panel faceplate and access cover.
- Inspect display connections for loose or corroded connectors.
- Test display backlight and segment operation.
- Check ribbon cable connections between display and interface board.
- Clean electrical contacts with contact cleaner.
- If display is faulty, disconnect ribbon cable.
- Remove mounting screws and replace display assembly.
- Reconnect ribbon cable and test display functions.
- Run diagnostic mode to verify proper display operation.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Kenmore error codes: Kenmore Error Codes