Problem: Heating element thermistor fault (models with water heater)
How to Fix tE1 Error
- Access thermistor at bottom of tub near heating element (requires draining tub completely).
- Disconnect power and verify tub empty before servicing.
- Measure resistance as per tE procedure at ambient temperature.
- Check connector for mineral deposits causing poor contact – clean with electrical contact cleaner and small brush.
- Verify thermistor physically secured to tub with mounting clip (loose sensor gives False readings).
- Replace thermistor DC34-00024A if resistance out of spec.
- Verify heater element resistance separately (should read 20-30Ω) to rule out heater failure causing thermistor error.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.