Author: ApplianceFixGuide Team

  • How to Fix Whirlpool Dishwasher Error F19

    How to Fix Whirlpool Dishwasher Error F19

    Problem: Main Control Board (Internal Logic)

    How to Fix Dishwasher Error

    1. Disconnect power and water supply.
    2. Remove lower access panel and toe kick panel.
    3. Disconnect all water lines and drain hose.
    4. Disconnect all electrical connectors and label them.
    5. Remove 4 mounting screws securing dishwasher to cabinet frame.
    6. Carefully slide dishwasher out from under counter (get helper).
    7. Remove pump/motor assembly mounting bolts (6 bolts).
    8. Disconnect wire harnesses from pump/motor connectors.
    9. Remove old pump/motor assembly.
    10. Clean mounting surface and install new gaskets.
    11. Install new pump/motor assembly and secure mounting bolts to 15 inch-pounds in crisscross pattern.
    12. Reconnect all electrical and water connections.
    13. Slide dishwasher back into position and secure to cabinet.
    14. Restore utilities and test all functions through complete cycle.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error Flash-4

    How to Fix Kenmore Washer Error Flash-4

    Problem: Temperature sensor failure – incorrect readings

    How to Fix Washer Error

    1. Disconnect power at circuit breaker.
    2. Remove lower front access panel.
    3. Locate temperature sensor on tub or heater assembly.
    4. Disconnect electrical connector from sensor.
    5. Test sensor resistance with multimeter at room temperature.
    6. Compare readings to manufacturer specifications chart.
    7. If sensor is out of range, remove mounting screw and replace sensor.
    8. Check wiring harness for damage or corrosion.
    9. Clean sensor mounting area and ensure proper sealing.
    10. Reconnect electrical connector and test temperature readings during cycle.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error Flash-9

    How to Fix Kenmore Dryer Error Flash-9

    Problem: Blower wheel failure – airflow restriction

    How to Fix Dryer Error

    1. Turn off power supply.
    2. Remove rear access panel.
    3. Inspect blower wheel for debris, damage, or obstructions.
    4. Check blower wheel mounting and shaft for proper alignment.
    5. Test motor operation independently of blower wheel.
    6. If motor runs but blower wheel doesn’t turn, inspect drive belt.
    7. Remove mounting screws securing blower housing.
    8. Replace damaged blower wheel assembly or drive belt as needed.
    9. Reassemble components and verify proper alignment.
    10. Test airflow and drying performance after repairs.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Dishwasher Error F18

    How to Fix Whirlpool Dishwasher Error F18

    Problem: User Interface Console (Stuck Key)

    How to Fix Dishwasher Error

    1. Turn off power at circuit breaker.
    2. Remove lower access panel.
    3. Locate drain solenoid on side of pump assembly.
    4. Disconnect electrical connector from solenoid.
    5. Remove 2 mounting screws securing solenoid bracket.
    6. Carefully remove old solenoid and plunger assembly.
    7. Clean solenoid mounting surface and plunger shaft with fine sandpaper.
    8. Apply light grease to new plunger shaft.
    9. Install new solenoid assembly with new gasket.
    10. Secure mounting screws to 6 inch-pounds.
    11. Reconnect electrical connector.
    12. Reinstall access panel.
    13. Restore power and test drain cycle, listening for proper solenoid engagement click and complete drainage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error Flash-8

    How to Fix Kenmore Dryer Error Flash-8

    Problem: Thermal fuse failure – safety device tripped

    How to Fix Dryer Error

    1. Turn off power supply immediately.
    2. Allow dryer to cool completely.
    3. Remove rear access panel.
    4. Locate thermal fuse on heater housing or blower housing.
    5. Disconnect electrical connector from thermal fuse.
    6. Test thermal fuse continuity with multimeter.
    7. If thermal fuse is open, remove mounting screws and replace fuse.
    8. Inspect high limit thermostat and temperature sensor for proper operation.
    9. Check for airflow restrictions causing overheating.
    10. Restore power and test heating cycle with temperature monitoring.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error Flash-3

    How to Fix Kenmore Washer Error Flash-3

    Problem: Drain pump failure – water not draining properly

    How to Fix Washer Error

    1. Turn off power supply.
    2. Remove lower front access panel.
    3. Check drain hose for kinks, blockages, or improper routing.
    4. Remove drain pump access cover and clean debris from filter.
    5. Inspect drain pump impeller for damage or obstructions.
    6. Test drain pump motor resistance with multimeter.
    7. Check drain pump wiring for corrosion or damage.
    8. If pump is weak or clogged, disconnect electrical connector and hoses.
    9. Remove mounting screws and replace drain pump assembly.
    10. Test drain cycle timing and verify complete drainage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Dishwasher Error F17

    How to Fix Whirlpool Dishwasher Error F17

    Problem: Main Control Board (Memory/EEPROM)

    How to Fix Dishwasher Error

    1. Disconnect power at circuit breaker.
    2. Remove lower access panel.
    3. Locate diverter motor on top of circulation pump housing.
    4. Disconnect electrical connector from motor.
    5. Remove 3 mounting screws securing motor assembly.
    6. Carefully lift motor assembly off pump housing.
    7. Clean drive mechanism and check for binding in gears.
    8. Install new diverter motor assembly with new gasket.
    9. Secure mounting screws to 7 inch-pounds in sequence.
    10. Reconnect electrical connector.
    11. Reinstall access panel.
    12. Restore power and test upper/lower spray arm operation during wash cycle – should alternate properly between arms.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error Flash-7

    How to Fix Kenmore Dryer Error Flash-7

    Problem: High limit thermostat failure – safety shutdown

    How to Fix Dryer Error

    1. Turn off power supply immediately.
    2. Allow dryer to cool completely.
    3. Remove rear access panel.
    4. Locate high limit thermostat on heater housing.
    5. Disconnect electrical connector from thermostat.
    6. Test thermostat continuity with multimeter.
    7. If thermostat is open, remove mounting screws and replace thermostat.
    8. Inspect heater element for short circuits or grounding issues.
    9. Check wiring harness for damage or corrosion.
    10. Restore power and test heating cycle with temperature monitoring.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error Flash-2

    How to Fix Kenmore Washer Error Flash-2

    Problem: Water inlet valve failure – no water entering

    How to Fix Washer Error

    1. Turn off power and check household water supply valves.
    2. Verify water pressure at supply lines (minimum 20 PSI required).
    3. Remove lower front access panel.
    4. Inspect water inlet valve screens for debris or mineral buildup.
    5. Clean inlet valve filter screens with vinegar solution.
    6. Test inlet valve solenoids with multimeter for proper resistance.
    7. If valve is faulty, disconnect water supply lines and electrical connector.
    8. Remove mounting screws and replace water inlet valve assembly.
    9. Restore water and power connections.
    10. Test fill cycle operation and timing.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Dishwasher Error F16

    How to Fix Whirlpool Dishwasher Error F16

    Problem: Main Control Board (Processor Check)

    How to Fix Dishwasher Error

    1. Turn off power at circuit breaker.
    2. Open dishwasher door fully.
    3. Remove lower dish rack.
    4. Locate spray arm assembly on bottom of tub.
    5. Unscrew spray arm cap counterclockwise by hand.
    6. Lift out spray arm and soak in vinegar solution for 30 minutes.
    7. Clean all spray holes with toothpick or small brush to remove mineral deposits.
    8. Inspect chopper blade for damage or debris – clean thoroughly.
    9. Check filter screen around spray arm base for clogs.
    10. Reinstall spray arm and secure cap clockwise until tight.
    11. Replace lower rack.
    12. Restore power and test wash cycle, observing water spray pattern for proper coverage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.