Problem: Software overcurrent – current sensing circuit fault or False trigger
How to Fix 9C8 Error
- Power cycle washer (unplug 5 minutes) to clear transient fault.
- Test water level sensor/pressure switch DC96-01703G operation as per 4E procedure.
- Inspect pressure tube for cracks or moisture accumulation causing False high-level signal.
- Clear drain filter thoroughly – partial blockage can trigger False overcurrent during pump operation.
- If sensor tests good but error returns during drain cycle: replace main PCB DC92-01543A (faulty current sensing IC U
- .
- After PCB replacement, perform auto-calibration cycle per service manual to reset current thresholds.
- Verify proper drain hose height (max 96 inches) to prevent backpressure during pump operation.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Browse all Samsung error codes: Samsung Error Codes