⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.
Error Code: tE3 Difficulty: Hard
Problem: Thermistor signal out of range – PCB interpretation error or reference voltage fault
How to Fix tE3 Error
- Verify both main and inlet thermistors test within specification using resistance chart.
- Inspect all thermistor wiring harness connections at PCB (J3, J
- for corrosion or bent pins.
- Check for water intrusion in wire loom causing signal noise – look for green corrosion on connectors.
- Measure 5V reference voltage at thermistor input pins on PCB during operation (should read stable
- 0±
- 2V).
- If sensors and wiring good but error persists immediately on power-up: replace main control board DC92-01543A.
- After PCB replacement, perform auto-calibration cycle per service manual (Spin + Temp + Power, navigate to calibration menu).
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Samsung model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →Browse all Samsung error codes: Samsung Error Codes