Error Code: 5C Difficulty: Moderate
Problem: Drain pump obstruction or pressure switch fault causing False full-tub signal
How to Fix 5C Error
- Clear drain filter thoroughly.
- Disconnect pressure tube from pump housing and blow through entire length to clear blockages.
- Test pressure switch continuity while blowing into tube – should click open/close at approximately
- 5 PSI.
- Inspect pump volute for foreign objects (remove 3 screws securing pump to tub assembly).
- Rotate impeller manually – replace pump if binding or broken vanes detected.
- Check for siphoning: ensure drain hose has proper air gap at standpipe (not sealed airtight).
- Replace pressure switch DC61-02173A if no continuity change during pressure test or switch stuck closed.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Samsung model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.