Error Code: Dryer Difficulty: Moderate
Problem: Thermistor sub-code tE1: Exhaust thermistor fault (dual-sensor systems)
How to Fix Dryer Error
- UNPLUG dryer from electrical power.
- Remove rear access panel to access blower housing assembly.
- Locate exhaust thermistor (tE1 sensor) mounted on blower housing near exhaust duct. Disconnect wiring harness.
- Measure resistance across sensor terminals with multimeter at room temperature. Expected value: approximately 10kΩ (±10%).
- If reading is infinite, zero, or significantly deviates from specification, replace sensor.
- Remove mounting screw securing thermistor. Gently extract sensor from housing well.
- Clean mounting well with isopropyl alcohol. Apply thermal conductive paste to tip of new sensor.
- Install replacement thermistor using OEM part DC34-00040A. Secure mounting screw to 6 in-lbs torque. Route wiring away from heat sources.
- Reconnect harness. Reassemble panels. Restore power and verify temperature readings update accurately during operation.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Samsung model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →

Leave a Reply