How to Fix Maytag Refrigerator Error SY CF

⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.

Error Code: Refrigerator Difficulty: Moderate

Problem: Condenser fan motor failure or wiring fault interrupting communication with main control board

⚖️ Repair Decision
✅ WORTH FIXING

Parts under $100

How to Fix Refrigerator Error

  1. Pull refrigerator forward and unplug.
  2. Remove lower rear access panel.
  3. Locate condenser fan motor (mounted near compressor).
  4. Inspect for dust/debris blocking blades – clean condenser coils thoroughly first.
  5. Disconnect motor harness and test resistance: 50-150Ω indicates good motor.
  6. If motor seized or open circuit, replace condenser fan motor WPW
  7. Check voltage at harness: should read 120VAC when compressor runs. No voltage indicates failed relay on main control board W
  8. Reinstall panel and verify fan runs when compressor activates.

Recommended Replacement Part

OEM Part #: WPW10617115

Estimated Market Price: $65-120

Check Price & Availability →

Still Not Working?

If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.

⚡ Don’t Risk a DIY Fail!

Get the ‘Secret Service Mode’ Cheat Sheet for your Maytag model. Includes an easy-to-read list of every error code and quick diagnostic tips.

✅ Join 15,000+ DIYers • Instant PDF Download


Browse More Codes

📖 View All Error Codes

Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)

Expert: Mike Sullivan

EPA Section 608 Certified Technician with 18+ years experience.

Read Editorial Standards →