Error Code: Refrigerator Difficulty: Moderate
Problem: Service mode diagnostic: 4 flashes = damper motor fault (matches F4)
How to Fix Refrigerator Error
- Enter service mode and confirm 4-flash pattern.
- Access damper assembly in fresh food compartment upper rear.
- Test damper motor resistance (5k-15kΩ) and operation with direct 12VDC power.
- Replace damper motor WPW10662480 if seized or electrically open.
- Clear fault history via test #25 after verifying damper operation through multiple temperature cycles.