Error Code: Refrigerator Difficulty: Moderate

Problem: Freezer compartment thermistor fault – sensor reading implausible temperature indicating short circuit (<500Ω at room temp)

⚖️ Repair Decision
✅ WORTH FIXING

Parts under $100

How to Fix Refrigerator Error

  1. Unplug refrigerator.
  2. Access freezer thermistor behind rear interior panel near evaporator coils.
  3. Disconnect harness and measure resistance at room temperature: should read 8k-10kΩ.
  4. If reading <1kΩ (short circuit) or 0Ω, replace thermistor WPW
  5. Inspect sensor wiring for pinched sections against sharp metal edges in evaporator compartment.
  6. Check connector pins for moisture corrosion – clean with electrical contact cleaner if present.
  7. After replacement, verify temperature display stabilizes within 1 hour of operation.
  8. If F2 returns with new sensor, suspect main control board W10868991 ADC failure – test other thermistors to isolate fault.

Recommended Replacement Part

OEM Part #: WPW10383615

Estimated Market Price: $45-65

Check Price & Availability →

Still Not Working?

If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.

⚡ Don’t Risk a DIY Fail!

Get the ‘Secret Service Mode’ Cheat Sheet for your Maytag model. Includes an easy-to-read list of every error code and quick diagnostic tips.

✅ Join 15,000+ DIYers • Instant PDF Download


Browse More Codes

📖 View All Error Codes

Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)

Expert: Mike Sullivan

EPA Section 608 Certified Technician with 18+ years experience.

Read Editorial Standards →

Browse all Maytag error codes: Maytag Error Codes

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *