Error Code: 8-4 Difficulty: Moderate
Problem: Temperature Sensor Fault
How to Fix 8-4 Error
- Disconnect the dishwasher from power.
- In many Maytag models, the temperature sensor (thermistor) is integrated into the main control board and is not a separate, replaceable part.
- If you receive this error, it means the main control board has a fault and the entire board needs to be replaced.
- Access the main control board at the base of the unit, transfer the wiring to the new board, and install it.
Recommended Replacement Part
OEM Part #: Model Specific (Main Control Board)
Estimated Market Price: N/A
Check Price & Availability →Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.