Error Code: Dryer Difficulty: Moderate
Problem: Heater failure – heating element open circuit
How to Fix Dryer Error
- Turn off power at circuit breaker.
- Remove rear access panel.
- Disconnect electrical connections to heater element.
- Test heater element for continuity with multimeter.
- If element is open, remove mounting screws securing element.
- Carefully extract old heater element and clean mountin surface.
- Install new heater element with proper alignment.
- Torque mounting screws to manufacturer specifications.
- Reconnect electrical wiring and restore power.
- Test heating cycle operation and verify temperature rise.