⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.
Error Code: Dryer Difficulty: Moderate
Problem: Thermistor short circuit – temperature sensor failure
How to Fix Dryer Error
- Disconnect power at circuit breaker.
- Remove rear access panel.
- Locate thermistor sensor on blower housing or heater assembly.
- Disconnect electrical connector from thermistor.
- Test sensor resistance with multimeter at room temperature (should read 10k-12k ohms).
- If readings are zero ohms or erratic, remove mounting screws securing thermistor.
- Install new thermistor assembly with proper sealing.
- Reconnect electrical connector and secure mounting.
- Restore power and run test cycle to verify temperature readings.
- Clear error code through diagnostic mode.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Kenmore model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)