Error Code: E17 Difficulty: Moderate
Problem: Lint screen temperature sensor (NTC) error.
How to Fix E17 Error (Step-by-Step)
- Disconnect the power to the dryer by unplugging it and confirm the error stays cleared during a full test cycle.
- The lint screen NTC sensor is located in the lint filter housing. Remove the lint screen to access it.
- You may need to remove the top or front panel to get to the sensor’s wiring.
- Disconnect the wire connector from the NTC sensor and confirm the error stays cleared during a full test cycle.
- Remove the screw or clip holding the sensor in place and remove the old sensor.
- Install the new NTC sensor and secure it and confirm the error stays cleared during a full test cycle.
- Reconnect the wire connector, reassemble the dryer, and restore power.
- Turn the appliance off, wait about 2 minutes, then turn it back on.
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.