Author: ApplianceFixGuide Team

  • How to Fix Whirlpool Washer Error F22

    How to Fix Whirlpool Washer Error F22

    Problem: Door/lid lock failure – lock mechanism not engaging or sensing circuit fault

    How to Fix Washer Error

    1. Unplug washer and attempt manual door/lid release per model-specific procedure (usually pull tab near lock).
    2. Remove top panel (top-load) or lower kick panel (front-load) to access lock assembly.
    3. Inspect lock mechanism for physical obstructions preventing engagement.
    4. Disconnect lock wiring harness and measure resistance: primary coil should read 300-600 ohms, secondary 1000-1500 ohms.
    5. Check lock strike plate alignment – should engage smoothly without binding.
    6. Verify 120V AC reaches lock during operation (test at connector with door closed).
    7. Inspect wiring harness between lock and control board for damage near hinge areas.
    8. If lock tests electrically good but won’t engage, replace door lock assembly WPW
    9. If lock receives no power or error persists after replacement, replace main control board W
    10. After repair, verify lock engages within 3 seconds of cycle start and releases within 2 minutes after cycle completion.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error F20

    How to Fix Kenmore Washer Error F20

    Problem: No water detected – inlet valve failure or supply issue

    How to Fix Washer Error

    1. Turn off power and check household water supply valves.
    2. Verify water pressure at supply lines (minimum 20 PSI required).
    3. Remove lower front access panel.
    4. Inspect water inlet valve screens for debris or mineral buildup.
    5. Clean inlet valve filter screens with vinegar solution.
    6. Test inlet valve solenoids with multimeter for proper resistance.
    7. If valve is faulty, disconnect water supply lines and electrical connector.
    8. Remove mounting screws and replace water inlet valve assembly.
    9. Restore water and power connections.
    10. Test fill cycle operation and timing.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Washer Error F28

    How to Fix Whirlpool Washer Error F28

    Problem: Communication error between main control board (CCU) and user interface board

    How to Fix Washer Error

    1. Unplug washer for 2 minutes to reset communication bus.
    2. Remove top panel to access main control board (CCU) connections.
    3. Locate ribbon cable or multi-wire harness connecting CCU to user interface/display board.
    4. Disconnect and reconnect both ends of harness, inspecting for bent pins or corrosion.
    5. Check harness routing for pinch points between cabinet panels.
    6. Verify display board receives 5V DC from CCU (test at connector pins).
    7. Inspect display board for moisture damage or burnt components near communication IC.
    8. If harness tests good (continuity on all pins) but error persists, replace user interface board first (less expensive).
    9. If F28 returns after interface replacement, replace main control board W
    10. After repair, verify all display functions and button responses operate correctly through diagnostic mode.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Washer Error F30

    How to Fix Whirlpool Washer Error F30

    Problem: Dispenser system error – actuator failure or linkage binding

    How to Fix Washer Error

    1. Unplug washer and remove dispenser drawer completely.
    2. Clean all comparments thoroughly with warm water to remove detergent residue buildup.
    3. Inspect dispenser housing for cracks or warping that could bind mechanism.
    4. Remove top panel to access dispenser actuator motor mounted above dispenser.
    5. Manually rotate actuator cam to verify smooth operation through full cycle.
    6. Disconnect actuator wiring harness and measure resistance (should be 1500-2500 ohms).
    7. Check for 120V AC at actuator connector during dispenser cycle using multimeter.
    8. Inspect mechanical linkage between actuator and dispenser valves for binding or disconnection.
    9. If actuator doesn’t move or resistance is infinite, replace dispenser actuator assembly W
    10. Reassemble and run diagnostic dispenser test cycle verifying proper compartment sequencing.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error F82

    How to Fix Kenmore Dryer Error F82

    Problem: Door switch circuit failure

    How to Fix Dryer Error

    1. Disconnect power at circuit breaker.
    2. Remove front access panel.
    3. Locate door switch wiring harness.
    4. Inspect wiring for damage, corrosion, or loose connections.
    5. Test door switch continuity with multimeter.
    6. Check continuity of door switch circuit from control board.
    7. If switch is faulty, replace door switch assembly.
    8. If wiring is damaged, repair or replace wire harness section.
    9. Clean electrical contacts with contact cleaner.
    10. Restore power and test door switch operation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Washer Error F32

    How to Fix Whirlpool Washer Error F32

    Problem: Pressure switch failure – water level detection circuit fault

    How to Fix Washer Error

    1. Unplug washer and remove top panel to access pressure switch (mounted on right side wall).
    2. Disconnect electrical connector and pressure hose from switch.
    3. With hose disconnected, multimeter should show NO continuity across switch terminals.
    4. Gently blow into pressure hose while monitoring continuity – switch should close at approximately
    5. 5 PSI.
    6. Check pressure hose for cracks, kinks, or water accumulation (replace hose WPW10351854 if damaged).
    7. Verify hose connection at air dome on tub is secure and not clogged with detergent residue.
    8. If switch doesn’t change state when blowing, replace pressure switch W
    9. If switch tests good but error persists, check wiring harness continuity between switch and control board.
    10. If harness tests good, replace main control board W
    11. After repair, run diagnostic cycle verifying correct water level detection at multiple fill stages.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error F19

    How to Fix Kenmore Washer Error F19

    Problem: Communication timeout between user interface and main control

    How to Fix Washer Error

    1. Turn off power at circuit breaker.
    2. Unplug washer for 10 minutes to reset all control boards.
    3. Check all wire harness connections between control boards.
    4. Inspect communication ribbon cables for damage or loose connections.
    5. Clean electrical contacts with contact cleaner.
    6. Verify proper seating of all connectors.
    7. Restore power and test basic functions.
    8. If error persists, check for software updates through manufacturer.
    9. Test communication signals with diagnostic mode if available.
    10. As last resort, replace user interface or main control board.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Washer Error F5E1

    How to Fix Whirlpool Washer Error F5E1

    Problem: Door switch/latch failure – door not detected as closed

    How to Fix Washer Error

    1. Unplug washer and inspect door strike plate alignment on cabinet.
    2. Remove lower kick panel (front-load) or top panel (top-load) to access door switch assembly.
    3. Manually press door switch plunger – should click positively and show continuity change on multimeter.
    4. Check switch mounting screws for looseness causing misalignment.
    5. Inspect wiring harness at switch connector for corrosion or broken wires near hinge area.
    6. Measure resistance across switch terminals: open when door open, closed (0 ohms) when door closed.
    7. Verify door glass isn’t cracked causing improper closure force.
    8. If switch doesn’t change state or shows intermittent continuity, replace door switch/latch assembly WPW
    9. After replacement, verify door locks within 3 seconds of cycle start and washer won’t operate with door ajar.
    10. Test all cycles to confirm consistent door detection.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Washer Error F5E2

    How to Fix Whirlpool Washer Error F5E2

    Problem: Door lock failure – lock mechanism won’t engage or release

    How to Fix Washer Error

    1. Unplug washer and attempt manual door release using emergency pull tab (located behind lower kick panel).
    2. Remove kick panel to access door lock assembly mounted on door frame.
    3. Inspect lock hook for physical damage or debris preventing engagement.
    4. Disconnect lock wiring harness and measure resistance: primary coil 300-600 ohms, secondary 1000-1500 ohms.
    5. Check lock strike plate alignment – should engage smoothly without binding when door closes.
    6. Verify 120V AC reaches lock during operation (test at connector with door closed).
    7. Inspect wiring harness between lock and control board for damage near door hinge.
    8. If lock receives power but won’t engage, or resistance readings are infinite, replace door lock assembly WPW
    9. After replacement, verify lock engages within 3 seconds of cycle start and releases within 2 minutes after cycle completion.
    10. Test operation through multiple cycles to confirm reliable locking/unlocking.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error F81

    How to Fix Kenmore Dryer Error F81

    Problem: Door switch failure – door won’t close properly

    How to Fix Dryer Error

    1. Turn off power supply.
    2. Open dryer door fully.
    3. Inspect door latch mechanism for debris or physical damage.
    4. Check door strike plate alignment with latch mechanism.
    5. Test door switch continuity with multimeter.
    6. Inspect door gasket for damage or debris preventing seal.
    7. If door switch is faulty, disconnect electrical connector.
    8. Remove mounting screws and replace door switch assembly.
    9. Verify door alignment and proper closure force.
    10. Test door closure and cycle operation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.