Author: ApplianceFixGuide Team

  • How to Fix Whirlpool Dishwasher Error F02

    How to Fix Whirlpool Dishwasher Error F02

    Problem: Water Leak Detected

    How to Fix Dishwasher Error

    1. Shut off water supply.
    2. Remove kickplate and dry the base pan.
    3. Run a cycle to find the leak source (pump, hose, or seal).


    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error F9E1

    How to Fix Kenmore Washer Error F9E1

    Problem: Drain pump system error – pump failure or blockage

    How to Fix Washer Error

    1. Turn off power supply.
    2. Remove lower front access panel.
    3. Check drain hose for kinks, blockages, or improper routing.
    4. Remove drain pump access cover and clean debris from filter.
    5. Inspect drain pump impeller for damage or obstructions.
    6. Test drain pump motor resistance with multimeter.
    7. Check drain pump wiring for corrosion or damage.
    8. If pump is weak or clogged, disconnect electrical connector and hoses.
    9. Remove mounting screws and replace drain pump assembly.
    10. Test drain cycle timing and verify complete drainage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error FF

    How to Fix Kenmore Dryer Error FF

    Problem: Fan failure – blower wheel not rotating

    How to Fix Dryer Error

    1. Turn off power supply.
    2. Remove rear access panel.
    3. Inspect blower wheel for debris, damage, or obstructions.
    4. Check blower wheel mounting and shaft for proper alignment.
    5. Test motor operation independently of blower wheel.
    6. If motor runs but blower wheel doesn’t turn, inspect drive belt for damage.
    7. Remove mounting screws securing blower housing.
    8. Replace damaged blower wheel assembly or drive belt as needed.
    9. Reassemble components and verify proper alignment.
    10. Test airflow and drying performance after repairs.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Whirlpool Dishwasher Error F01

    How to Fix Whirlpool Dishwasher Error F01

    Problem: NTC Temperature Sensor Fault

    How to Fix Dishwasher Error

    1. Check wiring to the NTC sensor.
    2. Measure resistance of NTC (approx 58k ohms at 20C).
    3. If bad, replace NTC sensor.


    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Washer Error F8E1

    How to Fix Kenmore Washer Error F8E1

    Problem: Water supply error – no water detected during fill

    How to Fix Washer Error

    1. Turn off power and check household water supply valves.
    2. Verify water pressure at supply lines (minimum 20 PSI required).
    3. Remove lower front access panel.
    4. Inspect water inlet valve screens for debris or mineral buildup.
    5. Clean inlet valve filter screens with vinegar solution.
    6. Test inlet valve solenoids with multimeter for proper resistance.
    7. If valve is faulty, disconnect water supply lines and electrical connector.
    8. Remove mounting screws and replace water inlet valve assembly.
    9. Restore water and power connections.
    10. Test fill cycle operation and timing.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error PC

    How to Fix Kenmore Dryer Error PC

    Problem: Power cord failure – damaged wiring

    How to Fix Dryer Error

    1. Turn off power at circuit breaker.
    2. Remove rear access panel.
    3. Inspect power cord for visible damage, fraying, or burns.
    4. Disconnect power cord from terminal block inside dryer.
    5. Test each conductor for continuity with multimeter.
    6. Check terminal block connections for corrosion or loose terminals.
    7. If power cord is damaged, remove mounting screws securing cord strain relief.
    8. Install new power cord assembly with proper strain relief.
    9. Connect wires to terminal block following color coding (black-red-white-green).
    10. Restore power and test dryer operation with voltage verification.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Washer Error F32

    How to Fix Maytag Washer Error F32

    Problem: Long Drain / Pump Circuit Error

    How to Fix Washer Error

    1. Unplug the washer from power source.
    2. Check that the door seal is clean and free of debris.
    3. Remove the lower front access panel to access the door lock mechanism.
    4. Inspect the door strike plate for any damage or misalignment.
    5. Disconnect the electrical connector from the door lock assembly.
    6. Remove the mounting screws securing the door lock to the front panel.
    7. Carefully remove the old door lock assembly and inspect the locking mechanism.
    8. Install the new door lock assembly, ensuring proper alignment with the door strike.
    9. Reconnect the electrical connector and secure mounting screws.
    10. Test the door lock by closing the door and starting a cycle to verify it locks and unlocks properly.
    11. Check the door seal for any tears or damage that could cause air leaks.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Washer Error F31

    How to Fix Maytag Washer Error F31

    Problem: Motor Control Unit (MCU) Internal Failure

    How to Fix Washer Error

    1. Unplug the washer completely from power.
    2. Remove the lower front access panel to access the heating system.
    3. Turn off the circuit breaker for the washer at the main electrical panel.
    4. Locate the heating element and temperature sensor on the tub.
    5. Disconnect the electrical connectors from the heating element terminals.
    6. Use a wrench to remove the heating element mounting nut.
    7. Carefully pull out the old heating element and inspect for scale buildup or damage.
    8. Clean the eating element mounting hole with a cloth to remove any debris.
    9. Apply a small amount of plumber’s tape to the threads of the new heating element.
    10. Insert the new heating element and secure with the mounting nut.
    11. Reconnect electrical connectors and reassemble the access panel.
    12. Restore power and test the heating function.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Washer Error F30

    How to Fix Maytag Washer Error F30

    Problem: Dispenser Actuator / Linkage Error

    How to Fix Washer Error

    1. Unplug the washer from power source.
    2. Remove the lower front access panel to access the pump area.
    3. Locate the drain pump and check for any visible leaks around the pump housing.
    4. Place towels underneath to catch any water.
    5. Disconnect the electrical connector from the drain pump.
    6. Loosen the hose clamps on the drain hoses and remove them from the pump.
    7. Remove the mounting bolts securing the drain pump to the washer frame.
    8. Inspect the old pump for cracks in the housing or damaged seals.
    9. Install the new drain pump, ensuring proper alignment with the mounting holes.
    10. Reconnect the drain hoses with new clamps if necessary.
    11. Reconnect the electrical connector and test the drain function for leaks.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error Blinking Water/Door Lights

    How to Fix Maytag Refrigerator Error Blinking Water/Door Lights

    Problem: Intermittent door switch fault – microswitch making/breaking contact causing False door-open signals

    How to Fix Refrigerator Error

    1. Observe which door’s light blinks erratically – indicates faulty switch on that door.
    2. Remove door switch cover (typically snaps off).
    3. Depress switch plunger manually while monitoring continuity – should transition cleanly between open/closed states.
    4. If intermittent continuity, replace door switch WPW
    5. Inspect switch mounting for loose screws causing misalignment.
    6. If switches test good but blinking continues, main control board W10868991 has failed input circuit – replace board after verifying all switches/wiring.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.