Author: ApplianceFixGuide Team

  • How to Fix Maytag Dryer Error E2

    How to Fix Maytag Dryer Error E2

    Problem: Thermistor Failure (Legacy)

    How to Fix E2 Error

    1. Unplug the dryer or shut off its circuit breaker.
    2. The thermistor is a small sensor located on the blower housing or heater duct. You may need to remove the rear or front panel to access it.
    3. Disconnect the wire harness from the thermistor.
    4. Use a multimeter to test its resistance. At room temperature (around 77°F/25°C), it should read approximately 10,000 ohms. A significantly different reading, or a reading of infinity, means it’s faulty.
    5. Replace the thermistor, reconnect the wiring, and reassemble the dryer.

    As an Amazon Associate, we earn from qualifying purchases through links on this page.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F20

    How to Fix Maytag Dryer Error F20

    Problem: Heater Circuit Failure (Legacy)

    How to Fix F20 Error

    1. This is a heater circuit failure, functionally the same as code ’02’. Disconnect the dryer from power.
    2. Access the components on the heater duct, usually from the rear of the dryer.
    3. Test the thermal fuse for continuity. If it’s open (blown), replace it. A blown fuse often indicates an underlying problem like a clogged vent.
    4. Test the heating element for continuity. If it’s open, replace the element.
    5. After replacing parts, thoroughly clean the dryer’s entire vent path before use.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F23

    How to Fix Maytag Dryer Error F23

    Problem: Exhaust Thermistor Failure (Outlet)

    How to Fix F23 Error

    1. Disconnect the dryer from power.
    2. This code points to the exhaust (outlet) thermistor. It’s located on the blower housing where the air exits the drum.
    3. Remove the necessary panels to access the blower housing.
    4. Disconnect the thermistor’s wire harness and test its resistance with a multimeter. It should read around 10,000 ohms at room temperature.
    5. If the reading is incorrect, replace the thermistor.

    As an Amazon Associate, we earn from qualifying purchases through links on this page.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F24

    How to Fix Maytag Dryer Error F24

    Problem: Inlet Thermistor Failure

    How to Fix F24 Error

    1. Disconnect the dryer from power.
    2. This code points to the inlet thermistor, located on the heater box assembly.
    3. Remove the rear panel to access the heater box.
    4. Disconnect the wire harness from the inlet thermistor and test its resistance. Like the outlet thermistor, it should read around 10,000 ohms at room temperature.
    5. If the test fails, replace the thermistor.

    As an Amazon Associate, we earn from qualifying purchases through links on this page.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F26

    How to Fix Maytag Dryer Error F26

    Problem: Drive Motor Failure

    How to Fix F26 Error

    1. Disconnect the dryer from power at the circuit breaker.
    2. This error indicates the control board is not detecting motor movement. First, check if the drive belt is broken. If so, replace it.
    3. If the belt is intact, the drive motor has likely failed. This requires significant disassembly, including removing the drum.
    4. Once the motor is accessible, replace it.
    5. If a new motor does not solve the issue, the main control board is faulty and needs to be replaced.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F30

    How to Fix Maytag Dryer Error F30

    Problem: Restricted Exhaust Airflow (Legacy)

    How to Fix F30 Error

    1. This error means the dryer’s exhaust vent is severely clogged, which is a fire hazard. Unplug the dryer immediately.
    2. Detach the vent hose from the back of the dryer and from the wall.
    3. Use a vent cleaning brush kit or a vacuum to thoroughly clean the entire length of the vent duct, from the dryer to the outside of your home.
    4. Ensure the exterior vent flap opens freely.
    5. If your vent hose is old, crushed, or made of flimsy plastic, replace it with a new semi-rigid metal vent kit.

    As an Amazon Associate, we earn from qualifying purchases through links on this page.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F31

    How to Fix Maytag Dryer Error F31

    Problem: Low/No Line Voltage (Legacy)

    How to Fix F31 Error

    1. This error indicates a problem with the power supply to the dryer. The dryer is not receiving the required 240V.
    2. Check your home’s circuit breaker box. Find the two breakers for the dryer and flip them completely off, then back on.
    3. Ensure the dryer’s power cord is fully plugged into the wall outlet.
    4. If the problem persists, you have an issue with your home’s electrical wiring or outlet, and you must contact a qualified electrician. Do not attempt to repair this yourself.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F50

    How to Fix Maytag Dryer Error F50

    Problem: Motor / Drive Fault

    How to Fix F50 Error

    1. This is a general motor fault, similar to F
    2. Disconnect the dryer from power.
    3. Check the drive belt to ensure it is not broken or slipped off the pulleys.
    4. If the belt is fine, the drive motor is the most likely cause. This requires disassembling the dryer cabinet to access and replace the motor.
    5. If replacing the motor does not fix the error, the fault lies with the main control board, which will need to be replaced.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F6E2

    How to Fix Maytag Dryer Error F6E2

    Problem: Communication Error (UI → Main Board)

    How to Fix F6E2 Error

    1. Disconnect the dryer from power.
    2. This error indicates a communication problem between the main control board and the user interface (the panel with the buttons).
    3. Remove the top panel of the dryer to access both boards.
    4. Check the wire harness that connects the two boards. Unplug it and plug it back in firmly on both ends to ensure a good connection.
    5. If reseating the connection doesn’t work, the user interface assembly is likely faulty and needs to be replaced.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes

  • How to Fix Maytag Dryer Error F6E3

    How to Fix Maytag Dryer Error F6E3

    Problem: Communication Handshake Failure

    How to Fix F6E3 Error

    1. Disconnect the dryer from power.
    2. This is a more severe communication error. Access the main control board and user interface by removing the top panel.
    3. Check the wiring between the two boards for any damage or loose connections.
    4. If the wiring is good, the problem is a failed component. It can be difficult to determine which board is at fault. Technicians often start by replacing the main control board first.
    5. If that doesn’t work, the user interface is the faulty part.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.




    Browse all Maytag error codes: Maytag Error Codes