  • How to Fix Maytag Dryer Error F01

    How to Fix Maytag Dryer Error F01

    Problem: Main electronic control board failure or motor control circuit error

    How to Fix Dryer Error

    1. Disconnect power at circuit breaker for safety.
    2. Remove rear panel to access control board.
    3. Inspect board for burnt components, bulging capacitors, or scorch marks.
    4. Check motor wiring harness for damage or loose connections at both motor and board.
    5. Test motor windings with multimeter (should read 2-6 ohms between terminals).
    6. If motor tests good and wiring intact, replace main control board WPW
    7. Reconnect all harnesses securely before reassembly.
    8. Restore power and run diagnostic cycle to verify repair.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F02

    How to Fix Maytag Dryer Error F02

    Problem: User interface control board communication failure or stuck keypad

    How to Fix Dryer Error

    1. Power off dryer and unplug from outlet.
    2. Open top panel by removing screws along rear edge and sliding panel backward.
    3. Locate user interface board behind control panel.
    4. Disconnect all ribbon cables and wiring harnesses.
    5. Inspect for moisture damage, corrosion, or burnt traces on board.
    6. Test individual keypads with multimeter in continuity mode—press each button to verify proper contact closure.
    7. If any keypad shows continuous continuity (stuck), clean contacts with electronic contact cleaner.
    8. If cleaning fails or board shows damage, replace interface board WPW
    9. Reconnect all harnesses ensuring proper orientation of ribbon cables.
    10. Power on and test all functions.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F03

    How to Fix Maytag Dryer Error F03

    Problem: Front/inlet thermistor open circuit or short circuit

    How to Fix Dryer Error

    1. Unplug dryer and remove front lower panel (typically 2-3 screws at bottom).
    2. Locate thermistor WP35001191 mounted near blower housing inlet.
    3. Disconnect wiring harness from thermistor terminals.
    4. Set multimeter to resistance mode and measure across thermistor leads at room temperature (70°F/21°C).
    5. Expected reading: 10k-12k ohms. Open circuit (infinite resistance) or short circuit (near zero ohms) indicates failure.
    6. Remove mounting screw securing thermistor to housing.
    7. Install new thermistor WP35001191, ensuring sensor tip makes full contact with air stream.
    8. Reconnect wiring harness securely.
    9. Reinstall panel and run test cycle monitoring temperature readings if available in diagnostic mode.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F04

    How to Fix Maytag Dryer Error F04

    Problem: Exhaust thermistor failure or restricted airflow triggering thermal protection

    How to Fix Dryer Error

    1. Disconnect power and remove rear panel of dryer.
    2. Locate exhaust thermistor mounted on exhaust duct near heater assembly.
    3. Disconnect wiring harness and measure resistance with multimeter at room temperature.
    4. Expected reading: 10k-12k ohms at 70°F. Replace if reading is outside 5k-20k ohm range.
    5. Before replacing thermistor, inspect entire vent system: remove lint screen, check for blockages in flexible hose behind dryer, verify exterior vent flap operates freely.
    6. Clean blower wheel housing of lint buildup using vacuum and brush.
    7. Replace thermistor WP3392519 if faulty—remove mounting screw and install new sensor ensuring proper seating in duct wall.
    8. Reconnect wiring and reassemble.
    9. Test with short cycle while monitoring exhaust temperature (should reach 135-155°F for cotton cycles).

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F05

    How to Fix Maytag Dryer Error F05

    Problem: Thermal fuse blown due to overheating from restricted airflow or failing heating element

    How to Fix Dryer Error

    1. Disconnect power at circuit breaker.
    2. Remove rear panel to access blower housing.
    3. Locate thermal fuse WP3392519 mounted on blower housing (small white component with two wires).
    4. Disconnect wires and test for continuity with multimeter—no continuity indicates blown fuse.
    5. BEFORE replacing fuse, diagnose root cause: inspect entire vent system for blockages, check blower wheel for lint buildup or damage, verify drum rotates freely (bearing failure increases motor load causing overheating).
    6. Test heating element for grounded windings (should show no continuity between element terminals and metal housing).
    7. Replace thermal fuse WP
    8. Also replace high-limit thermostat WP3392914 as preventive measure since both fail from same overheating event.
    9. Reassemble and test with vent disconnected temporarily to verify proper operation before reconnecting full vent system.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F06

    How to Fix Maytag Dryer Error F06

    Problem: Motor thermal overload tripped due to excessive load or failing motor

    How to Fix Dryer Error

    1. Unplug dryer and remove front panel to access drum and motor.
    2. Manually rotate drum—should turn smoothly with moderate resistance. Excessive drag indicates bearing failure or foreign object obstruction.
    3. Remove belt and rotate drum again—if still difficult to turn, inspect drum rollers, idler pulley, and felt seals for wear/damage.
    4. With belt removed, test motor by powering dryer briefly (CAUTION: keep hands clear)—motor should start immediately and run smoothly.
    5. If motor hums but won’t start, test start capacitor WP3392519 (typically 5-8 MFD) with capacitance meter.
    6. If motor runs but overheats quickly, test motor windings for proper resistance (2-6 ohms main winding, 4-8 ohms start winding).
    7. Replace faulty component: motor WPW10438706 ($
    8. if windings failed, or capacitor WP3392519 ($
    9. if weak.
    10. Reinstall belt with proper tension (idler pulley should deflect 1/2-3/4 inch when pressed).
    11. Test full cycle monitoring for overheating.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F07

    How to Fix Maytag Dryer Error F07

    Problem: High-limit thermostat tripped due to overheating condition

    How to Fix Dryer Error

    1. Disconnect power and remove rear panel.
    2. Locate high-limit thermostat WP3392914 mounted on heater housing (typically near heating element terminals).
    3. Disconnect wiring harness and test for continuity with multimeter—no continuity indicates tripped/open thermostat.
    4. Inspect heater assembly for grounded element (element touching housing) which causes continuous heating.
    5. Check thermal fuse WP3392519 on blower housing—replace if blown (indicates severe overheating event).
    6. Verify blower wheel is intact and rotating properly (cracked wheel reduces airflow causing overheating).
    7. Replace high-limit thermostat WP
    8. Reconnect wiring ensuring terminals are fully seated.
    9. Before reassembly, clean entire exhaust path including lint screen housing and blower wheel.
    10. Test dryer with vent disconnected for first cycle to verify proper cycling (heater should cycle on/off every 45-60 seconds).

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F08

    How to Fix Maytag Dryer Error F08

    Problem: Thermal cut-off fuse blown (non-resettable safety device)

    How to Fix Dryer Error

    1. Power off at circuit breaker.
    2. Remove rear panel to access heater assembly.
    3. Locate thermal cut-off fuse WP3392519 mounted on heater housing near high-limit thermostat.
    4. Disconnect wires and test for continuity—no continuity confirms blown fuse.
    5. CRITICAL: Thermal cut-off only blows during severe overheating. MUST diagnose root cause before replacement: inspect heating element for grounded windings, verify blower wheel integrity and rotation, check entire vent system for blockages, test high-limit thermostat operation.
    6. Replace thermal cut-off fuse WP
    7. Strongly recommended to replace high-limit thermostat WP3392914 simultaneously since both exposed to same overheating event.
    8. Clean blower housing thoroughly of lint buildup.
    9. Reassemble and test with short cycle while monitoring exhaust temperature with infrared thermometer (should not exceed 180°F).

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F09

    How to Fix Maytag Dryer Error F09

    Problem: Moisture sensor circuit failure or shorted sensor bars

    How to Fix Dryer Error

    1. Unplug dryer and open door.
    2. Locate two stainless steel moisture sensor bars inside drum opening near lint filter housing.
    3. Clean sensor bars thoroughly with isopropyl alcohol and soft cloth—remove all fabric softener residue, lint, and debris.
    4. Inspect for physical damage or metal objects (coins, pins) bridging the two sensor bars causing short circuit.
    5. Remove front lower panel to access sensor wiring harness connection at main control board.
    6. Disconnect harness and measure resistance across sensor terminals at board—should read 1-2 megohms when dry. Near-zero resistance indicates shorted sensors.
    7. If cleaning doesn’t resolve issue and sensors show short, replace moisture sensor assembly WPW
    8. Route new harness carefully avoiding pinch points near drum.
    9. Reconnect to control board and verify secure connection.
    10. Run diagnostic mode (consult model-specific procedure) to test sensor operation before normal use.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dryer Error F10

    How to Fix Maytag Dryer Error F10

    Problem: Control board EEPROM failure or corrupted software

    How to Fix Dryer Error

    1. Disconnect power for 5 minutes to attempt soft reset—this clears temporary memory errors.
    2. Restore power and check if error persists.
    3. If error remains, enter diagnostic mode per model-specific procedure (typically holding two buttons during power-on).
    4. Run all diagnostic tests, noting any additional fault codes stored in memory.
    5. Check all wiring harnesses connected to main control board WPW10111608 for loose connections, corrosion, or damage—reseat each connector firmly.
    6. Inspect board for visible damage: burnt components, leaking capacitors, or water damage.
    7. If board appears physically intact but error persists after harness inspection, EEPROM corruption is likely.
    8. Replace main control board WPW10111608 with exact model match.
    9. After installation, enter setup mode to configure cycle options and language settings per manufacturer instructions.
    10. Run full diagnostic cycle to verify all functions operate correctly.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.