Author: ApplianceFixGuide Team

  • How to Fix Kenmore Refrigerator Error OF

    How to Fix Kenmore Refrigerator Error OF

    Problem: Open freezer thermistor circuit (253 series upright freezer code)

    How to Fix Refrigerator Error

    1. UNPLUG freezer.
    2. Remove interior panel to access evaporator and thermistor.
    3. Locate freezer temperature sensor clipped to evaporator coil.
    4. Disconnect connector and test resistance (should read 5k-15k ohms).
    5. If reading OL (open circuit), replace thermistor.
    6. Ensure new sensor makes full contact with evaporator tubing.
    7. Secure with original clip or high-temp adhesive.
    8. Restore power and verify temperature display returns to normal within 10 minutes.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Refrigerator Error PF

    How to Fix Kenmore Refrigerator Error PF

    Problem: Power failure detected – unit lost AC power temporarily

    How to Fix Refrigerator Error

    1. Verify household power restored to outlet.
    2. Check circuit breaker hasn’t tripped.
    3. Press any control panel button to acknowledge power restoration.
    4. Display will show ‘PF’ for 5 seconds then return to normal operation.
    5. No parts replacement needed – this is informational code only.
    6. If temperatures rose significantly during outage, allow 4-6 hours for unit to re-stabilize before adding new food items.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Refrigerator Error DE

    How to Fix Kenmore Refrigerator Error DE

    Problem: Defrost system error – extended defrost cycle detected

    How to Fix Refrigerator Error

    1. UNPLUG unit and manually defrost until all ice melts from evaporator coils.
    2. Remove evaporator cover panel in freezer.
    3. Test defrost heater for continuity (should read 20-50 ohms).
    4. Test defrost thermostat when cold (should read closed).
    5. Test defrost timer/adaptive control operation (should advance to defrost mode every 8-12 hours compressor run time).
    6. Replace faulty component causing incomplete defrost (heater most common).
    7. Clean evaporator coils thoroughly after defrosting.
    8. Monitor for 3 complete defrost cycles to verify heater activates and terminates properly without triggering DE code again.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Refrigerator Error 6 BLINK

    How to Fix Kenmore Refrigerator Error 6 BLINK

    Problem: Compressor overload or start system failure (795 series flash code)

    How to Fix Refrigerator Error

    1. UNPLUG unit for 30 minutes to allow compressor thermal overload to reset.
    2. Restore power and listen for compressor attempting to start (brief hum then shutdown indicates overload).
    3. Remove rear access panel to access compressor.
    4. Replace start relay/overload kit first (least expensive component).
    5. If compressor still won’t start, test compressor windings for shorts/opens (requires multimeter).
    6. If windings good but compressor locked (won’t rotate shaft with screwdriver), install hard start booster capacitor as temporary fix.
    7. If windings shorted or compressor seized permanently, requires sealed system repair by licensed technician (refrigerant handling required).
    8. NEVER operate compressor with hard start device for >30 days – causes permanent damage.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY EF

    How to Fix Maytag Refrigerator Error SY EF

    Problem: Evaporator fan motor failure or wiring fault preventing communication with main control board

    How to Fix Refrigerator Error

    1. Unplug refrigerator for safety.
    2. Remove freezer rear interior panel to access evaporator assembly.
    3. Inspect fan blade for ice obstruction or physical damage.
    4. Disconnect fan motor harness and test resistance: should read 50-200Ω across motor terminals.
    5. If open/infinite resistance, replace evaporator fan motor WPW
    6. Check wiring harness between fan and main control board WPW10868991 for pinched wires or corroded connectors at J2 connector.
    7. Reassemble and verify fan operates during cooling cycle.
    8. Clear code by pressing Door Alarm + Freezer Temp Down for 3 seconds.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY CF

    How to Fix Maytag Refrigerator Error SY CF

    Problem: Condenser fan motor failure or wiring fault interrupting communication with main control board

    How to Fix Refrigerator Error

    1. Pull refrigerator forward and unplug.
    2. Remove lower rear access panel.
    3. Locate condenser fan motor (mounted near compressor).
    4. Inspect for dust/debris blocking blades – clean condenser coils thoroughly first.
    5. Disconnect motor harness and test resistance: 50-150Ω indicates good motor.
    6. If motor seized or open circuit, replace condenser fan motor WPW
    7. Check voltage at harness: should read 120VAC when compressor runs. No voltage indicates failed relay on main control board W
    8. Reinstall panel and verify fan runs when compressor activates.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY IC

    How to Fix Maytag Refrigerator Error SY IC

    Problem: Ice maker communication failure due to faulty ice maker module, wiring harness damage, or control board issue

    How to Fix Refrigerator Error

    1. Unplug refrigerator.
    2. Remove ice bin and inspect ice maker mold for jammed cubes – clear any obstructions.
    3. Locate ice maker module (typically upper freezer wall).
    4. Disconnect harness and inspect for corrosion/water damage at connector pins.
    5. Test ice maker thermostat continuity: should close below 15°F.
    6. Manually advance ice maker by inserting insulated screwdriver into test terminals to verify harvest cycle operation.
    7. If no response, replace ice maker assembly WPW
    8. If ice maker tests good but code persists, check wiring harness WPW10312695 between ice maker and main board.
    9. Last resort: replace main control board W10868991 after verifying all other components.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY CE

    How to Fix Maytag Refrigerator Error SY CE

    Problem: Communication error between user interface board and main control board during power-up sequence

    How to Fix Refrigerator Error

    1. Unplug refrigerator for 15 minutes to reset electronics.
    2. After reboot, if code returns: remove kickplate grille and locate main control board (rear lower compartment).
    3. Inspect all wire harness connections – especially J1 (power) and J7 (UI communication) – for loose/corroded pins.
    4. Disconnect and reconnect each connector 3 times to clean contacts.
    5. Check continuity of communication wires (typically white/red pair) between UI board WPW10366217 and main board W
    6. Test UI board output: with multimeter on DC voltage, measure between J7 pins 1-2 while pressing display buttons – should fluctuate 3-5VDC.
    7. If no signal, replace UI board.
    8. If signal present but main board doesn’t respond, replace main control board W
    9. After replacement, MUST program board using model-specific code from serial plate (e.g.,
    10. via Door Alarm + Freezer Down key sequence.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY RC

    How to Fix Maytag Refrigerator Error SY RC

    Problem: Relay control fault on main board – compressor or damper relay stuck open/closed causing temperature regulation failure

    How to Fix Refrigerator Error

    1. Unplug unit.
    2. Remove rear lower access panel to expose main control board W
    3. Visually inspect board for burnt components near relay locations (K1 compressor relay, K2 damper relay).
    4. With power restored briefly (use extreme caution), measure voltage at compressor terminals during cooling demand – should read 120VAC when relay energizes.
    5. If no voltage but board receives proper input signals, relay has failed internally.
    6. Check damper operation in fresh food section: should open/close during temperature changes. Stuck damper indicates failed damper motor WPW10662480 OR relay controlling it.
    7. Replace main control board W10868991 if relay tests faulty.
    8. IMPORTANT: After replacement, enter programming mode (Door Alarm + Freezer Down 3 sec), input correct program code from serial plate sticker, then press Freezer Down until code flashes to save. Failure to program correctly causes PE0000 error.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Refrigerator Error SY E2

    How to Fix Maytag Refrigerator Error SY E2

    Problem: Freezer thermistor out of range – sensor reading implausible temperature (< -25°F or > 80°F) indicating open/short circuit

    How to Fix Refrigerator Error

    1. Unplug refrigerator.
    2. Locate freezer thermistor: behind rear interior panel near evaporator coils (small white sensor clipped to evaporator tubing).
    3. Disconnect thermistor harness.
    4. Measure resistance at room temperature (70°F): should read 8,000-10,000Ω. At 32°F: ~7,964Ω. At 0°F: ~23,345Ω.
    5. If reading infinite (open) or 0Ω (short), replace thermistor WPW
    6. If resistance within spec, check wiring harness continuity back to main board J3 connector – look for pinched wires near hinge areas.
    7. If wiring good but code persists, test defrost thermostat WPW10316428 (clipped to evaporator) – should read closed below 40°F.
    8. Last resort: main control board W10868991 has failed ADC circuit – replace board and reprogram.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.