How to Fix Maytag Refrigerator Error LED Flash Code 8

⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.

Error Code: Refrigerator Difficulty: Moderate

Problem: Service mode diagnostic: 8 flashes = evaporator fan fault (matches F8/SY EF)

⚖️ Repair Decision
✅ WORTH FIXING

Parts under $100

How to Fix Refrigerator Error

  1. Enter service mode and confirm 8-flash pattern.
  2. Access evaporator compartment and test fan motor.
  3. Replace evaporator fan motor WPW10342223 if seized or electrically open.
  4. Clear fault history via test #25 after verifying fan operation during cooling cycle.

Recommended Replacement Part

OEM Part #: WPW10342223

Estimated Market Price: $75-115

Check Price & Availability →

Still Not Working?

If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.

⚡ Don’t Risk a DIY Fail!

Get the ‘Secret Service Mode’ Cheat Sheet for your Maytag model. Includes an easy-to-read list of every error code and quick diagnostic tips.

✅ Join 15,000+ DIYers • Instant PDF Download


Browse More Codes

📖 View All Error Codes

Most DIY parts are $50–$250. If you have a quote, use the total.