Error Code: Refrigerator Difficulty: Hard
Problem: Service mode diagnostic: 6 flashes = user interface board fault (matches F6)
How to Fix Refrigerator Error
- Enter service mode and confirm 6-flash pattern.
- Test UI board power input (12-14VDC) and communication signals.
- Replace user interface board WPW10366217 if unresponsive.
- Clear fault history via test #25 after successful board initialization.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.