Skip to main content
Appliance Fix Guide

Maytag Refrigerator error code

Maytag Refrigerator Error DE

Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items

Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items protruding).

EasyStart with 5-15 minutes of safe checks
⚠️ CHECK WARRANTY / AGE$100 - $250 Range
Maytag refrigerator repair guide for error DE
Error codeDERefrigerator

Start here before buying a part or taking the appliance apart.

  1. 1
    Visually inspect both doors for obstructions (ice buckets,

    Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items protruding).

  2. 2
    Check door gaskets for tears/ripping that prevent sealing

    Check door gaskets for tears/ripping that prevent sealing.

  3. 3
    Test door switches

    Test door switches: locate microswitches at door frame (typically 2 per door). With door closed, switch plunger should depress fully.

A quick explanation

What does DE mean?

Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items protruding).

The answer you came for

How to fix Maytag refrigerator error DE

Start with the safest checks and work from simple to technical.

  1. 1

    Visually inspect both doors for obstructions (ice buckets,

    Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items protruding).

  2. 2

    Check door gaskets for tears/ripping that prevent sealing

    Check door gaskets for tears/ripping that prevent sealing.

  3. 3

    Test door switches

    Test door switches: locate microswitches at door frame (typically 2 per door). With door closed, switch plunger should depress fully.

  4. 4

    Disconnect switch harness and test continuity

    Disconnect switch harness and test continuity: should read closed circuit when plunger depressed.

  5. 5

    Replace faulty door switch WPW10358373 (typically $12-18 each)

    Replace faulty door switch WPW10358373 (typically $12-18 each).

  6. 6

    If switches test good but code persists, check

    If switches test good but code persists, check wiring harness continuity between switches and main board.

  7. 7

    Rare case

    Rare case: main control board W10868991 misreading switch inputs – replace board only after verifying all switches/wiring.

Read the additional checks from the current guide

How to Fix Refrigerator Error Visually inspect both doors for obstructions (ice buckets, drawers not fully closed, food items protruding).Check door gaskets for tears/ripping that prevent sealing.Test door switches: locate microswitches at door frame (typically 2 per door). With door closed, switch plunger should depress fully.Disconnect switch harness and test continuity: should read closed circuit when plunger depressed.Replace faulty door switch WPW10358373 (typically $12-18 each).If switches test good but code persists, check wiring harness continuity between switches and main board.Rare case: main control board W10868991 misreading switch inputs – replace board only after verifying all switches/wiring. As an Amazon Associate, we earn from qualifying purchases through links on this page.

If the code comes back

Do not keep replacing parts based only on the code. Repeat the safe checks above. If the fault remains, stop and arrange qualified service rather than ordering from the code alone.

Recommended part

Recommended part for this error code

Part listed in the current guide

OEM candidate: WPW10358373

Price noted in the current guide: $25-185

Why this part is shown: It is associated with Maytag Refrigerator error DE in the current guide. The error code alone does not prove this part has failed.

Compatibility varies by model. Confirm that the Amazon listing includes your complete refrigerator model number before ordering.

Amazon part link View recommended part on Amazon

You can open the recommendation now. Check model compatibility on the Amazon page before purchasing.

Affiliate disclosure: qualifying purchases may earn this site a commission at no additional cost to you.

Replacement options

Ready to replace your refrigerator?

If repairing this refrigerator no longer feels worthwhile, compare three replacement paths below.

Why shop your replacement on Amazon?

  • Fast, free delivery

    Prime members can get fast, free delivery on eligible items.

  • Convenient delivery options

    Select large appliances may offer scheduled or Room of Choice delivery.

  • Haul-away options

    Haul-away may be available for select appliances and delivery areas.

  • Installation help

    Installation or assembly may be available on select items.

Delivery and service options, fees, and availability vary by item, seller, and delivery ZIP code. Confirm available services at Amazon checkout.

Affiliate disclosure: qualifying purchases may earn this site a commission at no additional cost to you.

Make the money decision

Repair or replace calculator

Use the age and total repair estimate to get a simple comparison. This is guidance, not a guarantee.

Safety first

Disconnect power before opening panels or touching internal parts.

When to stop
  • Stop if you see burned wiring, melted connectors, water near electrical parts, or a gas smell.
  • Do not perform live-voltage testing unless you are trained and equipped for it.
  • Use the exact model manual or service information before replacing electronic controls.

Free quick sheet

Get the Maytag Refrigerator Error Code Quick Sheet

A concise reference with code meanings, severity, first checks, and when it is time to stop and call for service.

No spam. Unsubscribe anytime.