Error Code: Dryer Difficulty: Moderate
Problem: Inlet and exhaust thermistor readings differ by more than 30°F indicating sensor mismatch or airflow problem
How to Fix Dryer Error
- Disconnect power and remove both front lower panel and rear panel for access to both thermistors.
- Locate inlet thermistor WP35001191 (front/blower housing) and exhaust thermistor WP3392519 (rear/exhaust duct).
- Disconnect both thermistors and measure resistance simultaneously with two multimeters or swap positions to verify readings match within 5%.
- If one thermistor reads significantly different, replace that sensor.
- If both thermistors test within specification, diagnose airflow restriction: remove lint screen and clean thoroughly, inspect flexible vent hose for kinks/crushing, verify exterior vent flap opens freely, clean blower wheel housing of lint buildup.
- Check drum seals for tears allowing air bypass.
- Replace faulty thermistor(s)—WP35001191 for inlet, WP3392519 for exhaust.
- Reassemble and run test cycle with vent disconnected temporarily to verify proper temperature differential (exhaust should run 20-30°F hotter than inlet during heating).
- Reconnect vent system and verify F3E4 does not return.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Maytag model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →

Leave a Reply