⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.
Error Code: Washer Difficulty: Moderate
Problem: Overflow condition detected – pressure switch stuck closed or control board fault
How to Fix Washer Error
- Unplug washer immediately to prevent flooding.
- Check base pan for standing water indicating actual overflow.
- Remove top panel to access pressure switch mounted on right side wall.
- Disconnect pressure hose from switch and blow through it to clear moisture/debris.
- With hose disconnected, multimeter should show NO continuity across switch terminals.
- Reconnect hose and gently blow into it while monitoring continuity (should close at ~
- 5 PSI).
- If switch stuck closed (always shows continuity), replace pressure switch W
- Inspect pressure hose for cracks, kinks, or water accumulation (replace if damaged).
- If switch tests good but error persists, replace main control board W
- After repair, run diagnostic cycle monitoring water level detection.
As an Amazon Associate, we earn from qualifying purchases through links on this page.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Whirlpool model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →Browse all Whirlpool error codes: Whirlpool Error Codes


Leave a Reply