Error Code: LC1 Difficulty: Moderate
Problem: Overflow condition detected by leak sensor system – tub overfilled
How to Fix LC1 Error
- Tilt machine backward to drain base pan water completely.
- Inspect pressure tube connection at tub top air dome – disconnected tube causes continuous fill.
- Test water level sensor DC96-01703C operation (blow into tube while monitoring switch continuity – should toggle at
- 5 PSI).
- Check inlet valve for sticking open – enter diagnostic mode to cycle valve operation 5 times.
- Replace water level sensor if switch fails to activate at proper pressure or frequency output unstable.
- Replace leak sensor DC96-01703A if base pan dry but error persists (False trigger from mineral deposits).
- Verify drain pump activates before next fill cycle to prevent cumulative overfill – test pump operation in diagnostic mode.