How to Fix Samsung Refrigerator Error 93E

⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.

Error Code: Refrigerator Difficulty: Moderate

Problem: Water tank heater fault; heater element open circuit or thermostat failure in water reservoir

⚖️ Repair Decision
✅ WORTH FIXING

Parts under $100

How to Fix Refrigerator Error

  1. Unplug refrigerator from electrical power. Turn off water supply valve.
  2. Remove interior panels to access water tank assembly (typically in fresh food compartment).
  3. Disconnect electrical wiring harness from water tank heater terminals.
  4. Test heater element resistance with multimeter: proper reading 30-80Ω. Infinite = open element.
  5. Test thermostat continuity mounted on water tank. Should be CLOSED when cold.
  6. Inspect heater element and wiring for visible damage, burns, or melted insulation.
  7. Drain water tank completely before proceeding with replacement.
  8. Remove mounting screws or clips securing water tank assembly. Extract old unit.
  9. Install new water tank assembly with heater using OEM part DA61-00125A. Ensure proper sealing.
  10. Reconnect wiring harness and water lines. Restore water and power. Verify water dispenser delivers properly chilled water without freezing issues.

Recommended Replacement Part

OEM Part #: DA61-00125A

Estimated Market Price: $68

Check Price & Availability →

Instant PDF Download • Factory Authorized

Still Not Working?

If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.

💬 Chat with a Certified Technician Now

⚡ Don’t Risk a DIY Fail!

Get the ‘Secret Service Mode’ Cheat Sheet for your Samsung model. Includes an easy-to-read list of every error code and quick diagnostic tips.

✅ Join 15,000+ DIYers • Instant PDF Download


Browse More Codes

📖 View All Error Codes

Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)

Expert: Mike Sullivan

EPA Section 608 Certified Technician with 18+ years experience.

Read Editorial Standards →

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *