Author: ApplianceFixGuide Team

  • How to Fix Kenmore Dishwasher Error E25

    How to Fix Kenmore Dishwasher Error E25

    Problem: Water level sensor fault or float switch failure

    How to Fix Dishwasher Error

    1. Check float switch assembly for proper movement and continuity.
    2. Inspect water level sensor tube for blockages or kinks.
    3. Test pressure switch operation at different water levels.
    4. Verify sensor wiring connections and resistance values.
    5. Replace water level sensor assembly if faulty.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dishwasher Error Flash-5-1

    How to Fix Maytag Dishwasher Error Flash-5-1

    Problem: Door not closed within 4 seconds or latch assembly failure

    How to Fix Dishwasher Error

    1. Turn off power at the circuit breaker.
    2. Inspect the door gasket for damage or debris.
    3. Check door hinges for proper alignment and smooth operation.
    4. Remove the inner door panel to access the latch mechanism.
    5. Test the door latch motor operation with a multimeter.
    6. Inspect the latch cam and striker for wear or damage.
    7. If the latch motor is faulty, disconnect the electrical connector.
    8. Remove mounting screws and replace the latch assembly.
    9. Ensure proper alignment with the strike plate.
    10. Test door closure timing and latch engagement.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dishwasher Error F2E2

    How to Fix Kenmore Dishwasher Error F2E2

    Problem: Water temperature sensor fault detected

    How to Fix Dishwasher Error

    1. Access temperature sensor and test resistance values.
    2. Compare readings to temperature chart specifications.
    3. Check sensor wiring harness for damage or corrosion.
    4. Verify sensor mounting and proper immersion in water.
    5. Test control board temperature sensor inputs.
    6. Replace temperature sensor if readings are out of range.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error F02

    How to Fix Kenmore Dryer Error F02

    Problem: Thermistor short circuit – temperature sensor failure

    How to Fix Dryer Error

    1. Disconnect power at circuit breaker.
    2. Remove rear access panel.
    3. Locate thermistor sensor on blower housing or heater assembly.
    4. Disconnect electrical connector from thermistor.
    5. Test sensor resistance with multimeter at room temperature (should read 10k-12k ohms).
    6. If readings are zero ohms or erratic, remove mounting screws securing thermistor.
    7. Install new thermistor assembly with proper sealing.
    8. Reconnect electrical connector and secure mounting.
    9. Restore power and run test cycle to verify temperature readings.
    10. Clear error code through diagnostic mode.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dishwasher Error Flash-4-1

    How to Fix Maytag Dishwasher Error Flash-4-1

    Problem: Too much force when closing door – door latch sensor issue

    How to Fix Dishwasher Error

    1. Disconnect power at the circuit breaker.
    2. Open the dishwasher door fully.
    3. Inspect the door latch assembly for physical damage.
    4. Check the door strike plate alignment with the latch mechanism.
    5. Remove the inner door panel to access the latch sensor.
    6. Test the door switch continuity with a multimeter.
    7. If the switch is faulty, disconnect the electrical connector.
    8. Remove mounting screws and replace the door latch assembly.
    9. Ensure proper alignment during installation.
    10. Test door closure force and smooth operation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dryer Error F01

    How to Fix Kenmore Dryer Error F01

    Problem: Main control board communication failure

    How to Fix Dryer Error

    1. Disconnect power at circuit breaker.
    2. Remove control panel access cover.
    3. Inspect main control board for burnt components or damaged traces.
    4. Check all wire harness connections for proper seating and corrosion.
    5. Test voltage supply to control board.
    6. If board shows physical damage, document all wire connections before removal.
    7. Remove mounting screws and disconnect all connectors.
    8. Install new main control board assembly.
    9. Reconnect all harnesses in correct positions.
    10. Power up and run diagnostic cycle to verify operation.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dishwasher Error Flash-3-1

    How to Fix Maytag Dishwasher Error Flash-3-1

    Problem: Break in electrical wiring OR thermistor failure

    How to Fix Dishwasher Error

    1. Turn off power at the circuit breaker.
    2. Remove the lower access panel and toe kick.
    3. Locate the temperature sensor (thermistor) on the tub wall.
    4. Disconnect the electrical connector and test sensor resistance.
    5. If sensor readings are out of range, remove the mounting screw and replace.
    6. If the sensor is good, inspect the entire wiring harness for cuts or damage.
    7. Test continuity of each wire between sensor and control board.
    8. Repair or replace damaged wiring sections with proper gauge wire.
    9. Use heat shrink tubing for all splices.
    10. Reassemble components and test the heating cycle.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dishwasher Error Flash-2-1

    How to Fix Maytag Dishwasher Error Flash-2-1

    Problem: Stuck key button on the control panel

    How to Fix Dishwasher Error

    1. Disconnect power at the circuit breaker.
    2. Remove the control panel faceplate and access cover.
    3. Inspect the membrane switch pad for physical damage or debris.
    4. Test each button contact with a multimeter for proper continuity.
    5. Clean button contacts with electrical contact cleaner and soft brush.
    6. If the membrane switch is damaged, disconnect the ribbon cable.
    7. Remove mounting screws and replace the entire control panel assembly.
    8. Reconnect the ribbon cable and test all button functions.
    9. Clear error code by cycling power.
    10. Verify proper operation of all controls.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Maytag Dishwasher Error Flash-1-1

    How to Fix Maytag Dishwasher Error Flash-1-1

    Problem: Stuck relay on the electronic control board

    How to Fix Dishwasher Error

    1. Turn off power at the circuit breaker and disconnect from power source.
    2. Remove the lower access panel and control panel cover.
    3. Document all wire connections before disconnecting.
    4. Inspect the control board for burnt relays or damaged components.
    5. Test relay continuity with a multimeter (should show open circuit when de-energized).
    6. If the relay is stuck closed, attempt to clean contacts with electrical contact cleaner.
    7. If cleaning fails, replace the entire control board assembly.
    8. Reconnect all harnesses in correct positions.
    9. Restore power and run a diagnostic cycle.
    10. Clear error codes and verify all functions.

    Still Not Working?

    If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.


  • How to Fix Kenmore Dishwasher Error F6F4

    How to Fix Kenmore Dishwasher Error F6F4

    Problem: Water inlet valve fault or restriction

    How to Fix Dishwasher Error

    1. Check water supply pressure and valve operation.
    2. Clean inlet valve screen and flow paths.
    3. Test valve solenoid resistance (800-1200 ohms).
    4. Verify voltage to inlet valve during fill cycle.
    5. Inspect valve for mechanical binding or debris.
    6. Replace water inlet valve assembly if faulty.

    Still Not Working?