Error Code: E1 Difficulty: Moderate
Problem: Indicates an issue with the thermistor, specifically an open circuit. This can be caused by a faulty thermistor or a wiring problem.
How to Fix E1 Error (Step-by-Step)
- Disconnect the dryer from the wall outlet to ensure safety.
- Access the thermistor, which is typically located on the blower housing. You may need to remove the lower front access panel by unscrewing it or releasing clips at the top.
- Locate the thermistor on the blower housing. It is a small black or gray component with a two-wire connector.
- Disconnect the wire harness attached to the thermistor. Squeeze the tab on the connector to release it.
- Remove the single screw, usually a quarter-inch hex head, that holds the thermistor in place.
- Install the new thermistor (Part: WP8577274), secure it with the screw, and firmly reconnect the wire harness.
- Reassemble the access panel, plug the dryer back in, and run a test cycle.
- Turn the appliance off, wait about 2 minutes, then turn it back on.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Amana model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →Browse all Amana error codes: Amana Error Codes


Leave a Reply