Error Code: Refrigerator Difficulty: Easy
Problem: Condenser fan undercurrent fault – insufficient current draw indicating open winding
How to Fix Refrigerator Error
- Unplug refrigerator and pull unit away from wall.
- Remove rear access panel to access condenser fan motor.
- Disconnect fan wiring harness and measure resistance across terminals (should read 50-200 ohms).
- If resistance is infinite (open circuit), motor windings have failed.
- Inspect motor connector for bent pins or corrosion.
- Check wiring harness for broken wires near vibration points.
- Verify 120V AC reaches fan connector during compressor operation.
- If voltage is present but motor doesn’t run and resistance is infinite, replace condenser fan motor WPW
- After replacement, verify fan runs continuously during compressor operation.
- Clean condenser coils thoroughly to ensure proper airflow and prevent premature motor failure.
As an Amazon Associate, we earn from qualifying purchases through links on this page.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Whirlpool model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →Browse all Whirlpool error codes: Whirlpool Error Codes


Leave a Reply