Error Code: F25 Difficulty: Moderate
Problem: Inlet Thermistor Shorted
How to Fix F25 Error
- Unplug the dryer. This code means the inlet thermistor has shorted.
- Remove the lower front toe panel or the large rear panel to get access to the internal components.
- Find the thermistor mounted on the blower housing.
- Disconnect the wires and remove the mounting screw.
- Secure the new thermistor in place and reconnect the wiring.
Recommended Replacement Part
OEM Part #: WP8577274 (Inlet Thermistor)
Estimated Market Price: $15-$35
Check Price & Availability →Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.