⚠️ Safety Warning: Appliance repair involves electricity, gas, and moving parts. Always disconnect power before working on any appliance.
Error Code: F24 Difficulty: Moderate
Problem: Inlet Thermistor Open
How to Fix F24 Error
- Unplug the dryer.
- This code indicates the inlet thermistor is ‘open’. Locate the thermistor on the blower housing or heater box.
- You will need to remove an access panel (usually the lower front or the rear) to see it.
- Disconnect the wire harness from the thermistor.
- Remove the screw holding it in place and install the new thermistor.
As an Amazon Associate, we earn from qualifying purchases through links on this page.
Recommended Replacement Part
OEM Part #: WP8577274 (Inlet Thermistor)
Estimated Market Price: $15-$35
Check Price & Availability →Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Whirlpool model. Includes an easy-to-read list of every error code and quick diagnostic tips.