Error Code: F24 Difficulty: Moderate
Problem: Inlet Thermistor Open
How to Fix F24 Error
- Unplug the dryer.
- This code indicates the inlet thermistor is ‘open’. Locate the thermistor on the blower housing or heater box.
- You will need to remove an access panel (usually the lower front or the rear) to see it.
- Disconnect the wire harness from the thermistor.
- Remove the screw holding it in place and install the new thermistor.
Recommended Replacement Part
OEM Part #: WP8577274 (Inlet Thermistor)
Estimated Market Price: $15-$35
Check Price & Availability →Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.