Error Code: Dryer Difficulty: Moderate
Problem: Thermistor sub-code tE2: Inlet thermistor fault (dual-sensor systems)
How to Fix Dryer Error
- UNPLUG dryer from electrical power.
- Remove front lower access panel or rear panel per model diagram to access inlet thermistor location.
- Locate inlet thermistor (tE2 sensor) mounted on air intake duct assembly. Disconnect wiring harness.
- Measure resistance across sensor terminals with multimeter at room temperature. Expected value: approximately 10kΩ (±10%).
- If reading is faulty, replace sensor.
- Remove retaining clip or screw securing thermistor. Carefully withdraw sensor from mounting location.
- Clean mounting area thoroughly. Apply thermal paste to sensing tip of new sensor.
- Install new thermistor using OEM part DC34-00041A. Secure mounting hardware. Route wiring clear of moving components.
- Reconnect harness. Reassemble panels. Restore power and verify temperature display functions correctly during cycle operation.
Recommended Replacement Part
Still Not Working?
If the replacement part didn’t fix the issue, you may have a wiring problem or main board failure.
⚡ Don’t Risk a DIY Fail!
Get the ‘Secret Service Mode’ Cheat Sheet for your Samsung model. Includes an easy-to-read list of every error code and quick diagnostic tips.
✅ Join 15,000+ DIYers • Instant PDF Download
Browse More Codes
📖 View All Error Codes
Most DIY parts are $50–$250. If you have a quote, use the total.
More options (for a better recommendation)
Expert: Mike Sullivan
EPA Section 608 Certified Technician with 18+ years experience.
Read Editorial Standards →

Leave a Reply